Skip to content
Image of D&W psiioSYSTEM x²
Template

D&W psiioSYSTEM x²

by LOXONEBrand: drexel und weissNo rating yet1,503 downloads

Description

Control your heat pump from drexel and weiss via RS232

Inputs and outputs · 31

NameTypeCommandUnit
Outside air temperatureCommLU 202 \v°C
CO2CommLU 230 \vppm
Fan speed exhaustCommLU 1186 \v1/min
Fan speed supplyCommLU 1184 \v1/min
Change fine particle filterCommLU 7004 \v<v>
Change coarse particle filterCommLU 7002 \v<v>
Error 1 (LU)CommLU 800 \v
Error 2 (LU)CommLU 7500 \v
Room temperatureCommWP 200 \v°C
Temperature solar panelCommWP 242 \v°C
Floor temperatureCommWP 216 \v°C
Error 1 (WP)CommWP 800 \v
Error 2 (WP)CommWP 7500 \v
Boiler temperature (EHZ)CommWP 212 \v°C
Mode_WLGCommLU 5002 \v<v>
Water set temperature (psiio)CommWP 5064 \v°C
Room set temperature (psiio)CommWP 5016 \v°C
Boiler temperature (solar)CommWP 244 \v°C
Flow low-temperature heating circuitCommWP 240 \v°C
Requirement: passive coolingCommWP 1142 \v
Boiler temperature (heat pump)CommWP 214 \v°C
Fan level 1CommLU 5002 1\n\r
Fan level 2CommLU 5002 2\n\r
Fan level 3CommLU 5002 3\n\r
Fan AutomaticCommLU 5002 4\n\rLU 1048 1\n\r
PartyCommLU 5002 5\n\r
Fan offCommLU 5002 0\n\r
Function bathroom +CommWP 5036 1\n\r
Function heating +CommWP 5492 1\n\r
Room set temperatureCommWP 5016 <v.1>\n\r°C
Water set temperatureCommWP 5064 <v>\n\r°C