Template

SMA Sunny Boy

by LOXONEBrand: SMANo rating yet2,202 downloads

Description

Read values of your SMA inverter via Modbus TCP.

Inputs and outputs · 12

NameTypeUnit
Inverter TypeModbus<v.1>
GridVoltageL1ModbusV
GridFrequentieModbusHz
PowerModbusW
DailyYieldModbusKwh
TotalYieldModbusKwh
TotalYield WhModbusWh
DC CurrentModbusA
DC VoltageModbusV
DC PowerModbusW
Heat sink temperatureModbus°C
Internal temperatureModbus°C

FAQ

No questions have been answered yet.

Ratings and comments

No ratings or comments yet.

Questions and answers

  1. Setting up a SMA Sunny Boy inverter via Modbus TCP library.

    Open

    Dear Sir/Madam,

    I'm about to add a Sunny Boy inverter into a Loxone controlled smarthome.

    I've found out this library which states that makes possible reading values of a SMA Sunny Boy inverter via Modbus TCP.

    When importing the Library into Loxone Config it states that there is a new Modbus device available. And the only way I can get into it is by adding a Modbus extension in Loxone Config.

    Here comes my question. Since Modbus TCP is communicating via Ethernet I understand that I do not need a Modbus Extension (which is using a RTU interface).

    Therefore, how can I do to set up the SMA Sunny Boy reader via Modbus TCP if a Modbus extension is not needed?

    Is it possible to have an example?

    With best regards,

    David Vives

    1 reply

    1. The note says "Modbus Extension, Modbus Server or a Modbus Air". If you go to Network Periphery and add a Modbus Server, then you can insert the template there.

  2. The values are wrong

    Open

    Hello, I have visualised the values of the registers and these values are correct. But they are not in the right context. e.g. Current in reality is 1.5 A. (with us, comma after 0) Living in Europe. Visually that then becomes 1,500.00 A bv2 : the temperature is -21212121212 °C Can I change this? It's of no use this way.

    2 replies

    1. Hello Jurgen,

      what is the language of the config you are using? What is the system language of the platform the app is runing.

      If the values are coming in correctly over modbus and in the app it is not correct this might have to do with a language setting of the platform the app will adapted the system language of the platform the app is running on.

    2. Hello,

      what is the language of the config you are using?

      => Loxone Config is dutch on windows pc

      What is the system language of the platform the app is runing.

      => Osx, iOS is dutch