M-TEC Heating & Cooling

by LOXONEBrand: M-TECNo rating yet1,357 downloads

Description

Control your M-TEC Heating & Cooling System via Modbus TCP. M-TEC with the [ZP022] Operating system can be directly connected to Loxone without a Gateway.

Depending on variation of your project you can choose between Miniserver, Miniserver Go or Miniserver Compact M-Tec also has its own PV management system with his own battery storage. The integration is shown in a separate template: M-TEC Energy Butler.


The Choice of paring M-TEC Systems with Loxone offers the possibility of:

- Integrating demand-based heating and cooling depending on e.g. presence or the protection of open windows, Automatic Shading and Weatherforecast. - Active integration in interaction with e.g. PV- systems in a Loxone Energy Management - Load management in areas where the building's electricity connection is low - Using flexible electricity tariffs with the Spot Price Optimizer. - Use statistics or individual notifications - Create individual live system schematics. - Reduce cycles and operating hours of your M-TEC Heatpump or Subdevices. - Combining hybrid solutions e.g. Heatpump and PV- Heating element in your Hot Water Storage - Create e.g. yearly operation goals like certain annual runtime forces for hybrid systems e.g. (Belaria 60% amount of energy, UltraGas 40% amount of energy) to fulfill the requirements of your local government. - Grid management according to §14a ENWG in Germany - Blackoutsafe! Switch off the Heatpump if the Grid power fails e.g. emergency power is active to safe battery capacity. - Use the flexible ways of reading thermal heat meters and electricity meters via e.g. M-Bus or IR readers and the thermal or electrical visualization in the Loxone Energy Flow Monitor. For e.g. Contractors. - Whether residential or commercial buildings. No matter whether M-TEC or Loxone is the main operator, no matter which hydraulics and consumers. Connecting M-TEC Heatpumps with Loxone systems allows the demand-oriented and intelligent distribution of energy thanks to distribution solutions from Belimo or IMI TA. - Influence on the hot water circulation pump by controlling via the presence detectors. - Increased security through leakage detection or activation of IP cameras in the plant room. - Use of the Heatpump to operate a Pool and to automatically control the switching of heating, cooling and hot water. - Connectivity and setup of heating centers and heating substations with the flexible ways of Loxone intercommunication.


M-TEC Helpcenter, download area and activation of Modbus:

- If you need help with e.g. the configuration of Modbus within the M-TEC operation unit please contact your M-TEC Partner. The Partner or the M-TEC customer service can be commissioned for this purpose. - To activate Modbus TCP on the M-TEC unit, please take a look on the following video, please note that the modbusadress is always "1". The Networksettings have to be common with the Loxone Config Settings on the Modbusserver.


Example UseCase: Integration M-TEC Brine System: Residential building with Heatpump, Hot Water storage, Heating/Cooling Buffer and Heating/Cooling circuits.

- [A1] Device Brine/Water e.g. M-TEC WPS - [A2] Passive Cooling with Ground Probe (Brine) - [A3] Heating/Cooling Buffer - [A4] Hot Water Storage Tank --> Controlled by Loxone - [A5] Fresh Water System - [HC1] Mixing Circuit Heating/Cooling HC1 (e.g. Ceiling Basement) --> Controlled by Loxone - [HC2] Mixing Circuit Heating/Cooling HC2 (e.g. Ceiling Groundfloor) --> Controlled by Loxone - [HC3] Mixing Circuit Heating/Cooling HC3 (e.g. Fancoils Office) --> Controlled by Loxone

With our step by step manual for collecting the Heating or Cooling Demand and forwarding it to the M-TEC WPS, we enable the interaction of the individual room control with the Central Heating & Cooling System of M-TEC. Please take a look on the Loxone Config sample file in the Library download area.

Inputs and outputs · 71

NameTypeUnit
State Heatpump Operating HoursModbush
Actual OutsidetemperatureModbus°C
State Hot Water OperatingmodeModbus<v>
Actual Hot Water temperatureModbus°C
State Target Roomtemperature HC1Modbus°C
Actual Operating mode HC1Modbus<v>
Actual Room Humidity HC1Modbus%
Actual Roomtemperature HC1Modbus°C
Actual Electrical Heatpump PowerModbusW
Actual Heatpump Thermal PowerModbuskW
State Heatpump OperationmodeModbus<v>
State Heatpump Total Electrical EnergyModbuskWh
Actual Operating mode HC2Modbus<v>
Actual Operating mode HC3Modbus<v>
Actual Room Humidity HC2Modbus%
Actual Room Humidity HC3Modbus%
Actual Roomtemperature HC2Modbus°C
Actual Roomtemperature HC3Modbus°C
State Target Roomtemperature HC2Modbus°C
State Target Roomtemperature HC3Modbus°C
State Heatpump ErrorModbus<v>
State Target Supplyflowtemperature HC1Modbus°C
Actual Supplyflowtemperature HC1Modbus°C
Actual Supplyflowtemperature HC2Modbus°C
Actual Supplyflowtemperature HC3Modbus°C
State Target Supplyflowtemperature HC2Modbus°C
State Target Supplyflowtemperature HC3Modbus°C
Actual Hot Water TargettemperatureModbus°C
Actual Buffertemperature TopModbus°C
State Heatpump operation stateModbus<v>
Actual Heatpump SupplyflowtemperatureModbus°C
Actual Heatpump BackflowtemperatureModbus°C
Actual Heatpump Brine IN TemperatureModbus°C
Actual Heatpump BrineOUT TemperatureModbus°C
State Heatpump TargetttemperatureModbus°C
State CompressorspeedModbus%
State Coolrequest BufferModbus<v>
State Coolrequest HC1Modbus<v>
State Coolrequest HC2Modbus<v>
State Coolrequest HC3Modbus<v>
State Heatrequest BufferModbus<v>
State Heatrequest HC1Modbus<v>
State Heatrequest HC2Modbus<v>
State Heatrequest HC3Modbus<v>
Actual Buffertemperature BottomModbus°C
HC. 1 normal room temperatureModbus°C
Set System Operation modeModbus<v>
HC. 1 offset room temperatureModbusK
Set Operationmode HC1Modbus<v>
Set cooling requirement HC1Modbus<v>
Set heating requirement HC1Modbus<v>
Set Target Supplyflowtemperature HC1Modbus°C
Set Hot Water TargettemperatureModbus°C
HC. 1 lower room temperatureModbus°C
Set Outside temperatureModbus°C
PV. current surplus powerModbuskW
Set Hot Water OperationmodeModbus<v>
HC. 2 lower room temperatureModbus°C
HC. 3 lower room temperatureModbus°C
Set Operationmode HC2Modbus<v>
Set Operationmode HC3Modbus<v>
Set heating requirement HC2Modbus<v>
Set heating requirement HC3Modbus<v>
Set cooling requirement HC2Modbus<v>
Set cooling requirement HC3Modbus<v>
HC. 2 normal room temperatureModbus°C
HC. 3 normal room temperatureModbus°C
HC. 2 offset room temperatureModbusK
HC. 3 offset room temperatureModbusK
Set Target Supplyflowtemperature HC2Modbus°C
Set Target Supplyflowtemperature HC3Modbus°C

FAQ

No questions have been answered yet.

Ratings and comments

No ratings or comments yet.

Questions and answers

  1. Blackoutsafe!

    Open

    Liebes M-TEC Loxone Team. Wie lässt sich die Wärmepumpe wie in der BEschreibung angeführt (Blackoutsafe) kontrolliert herunterfahren? Welche Aktor kann für das verwendet werden? Danke für die Hilfe mfg

    No replies

Report this entry

Report abuse

You have to be logged in to report an entry. Log in