Template
D&W psiioSYSTEM aerosilent
Description
Steuern Sie Ihre Wohnraumlüftung von drexel und weiss via RS232
Inputs and outputs · 18
| Name | Type | Command | Unit |
|---|---|---|---|
| Outside air temperature | Comm | LU 202 \v | °C |
| CO2 | Comm | LU 230 \v | ppm |
| Fan speed exhaust | Comm | LU 1186 \v | 1/min |
| Fan speed supply | Comm | LU 1184 \v | 1/min |
| Change fine particle filter | Comm | LU 7004 \v | <v> |
| Change coarse particle filter | Comm | LU 7002 \v | <v> |
| Error 1 (LU) | Comm | LU 800 \v | |
| Error 2 (LU) | Comm | LU 7500 \v | |
| Mode_WLG | Comm | LU 5002 \v | <v> |
| Room temperature | Comm | WP 200 \v | °C |
| Fan level 1 | Comm | LU 5002 1\n\r | |
| Fan level 2 | Comm | LU 5002 2\n\r | |
| Fan level 3 | Comm | LU 5002 3\n\r | |
| Fan automatic | Comm | LU 5002 4\n\rLU 1048 1\n\r | |
| Party | Comm | LU 5002 5\n\r | |
| Fan off | Comm | LU 5002 0\n\r | |
| Heating PLUS function | Comm | WP 5492 1\n\r | |
| Room setpoint temperature | Comm | WP 5016 <v.1>\n\r | °C |