Steuern Sie Ihre Wohnraumlüftung von drexel und weiss via RS232

Inputs and outputs · 18

NameTypeCommandUnit
Outside air temperatureCommLU 202 \v°C
CO2CommLU 230 \vppm
Fan speed exhaustCommLU 1186 \v1/min
Fan speed supplyCommLU 1184 \v1/min
Change fine particle filterCommLU 7004 \v<v>
Change coarse particle filterCommLU 7002 \v<v>
Error 1 (LU)CommLU 800 \v
Error 2 (LU)CommLU 7500 \v
Mode_WLGCommLU 5002 \v<v>
Room temperatureCommWP 200 \v°C
Fan level 1CommLU 5002 1\n\r
Fan level 2CommLU 5002 2\n\r
Fan level 3CommLU 5002 3\n\r
Fan automaticCommLU 5002 4\n\rLU 1048 1\n\r
PartyCommLU 5002 5\n\r
Fan offCommLU 5002 0\n\r
Heating PLUS functionCommWP 5492 1\n\r
Room setpoint temperatureCommWP 5016 <v.1>\n\r°C