ZCS Azzurro HYD 10000 ZSS/HYD 20000 ZSS - Three-Phase Hybrid Inverter - Modbus
Content languageEnglish
Description
Template for the integration of an Azzurro 3-phase inverter with ZSM-ETH-EXT or ZSM-WIFI-EXT stick logger. The Modbus data is transmitted via the IP of the stick logger and port 8899.
Inputs and outputs · 31
| Name | Type | Unit |
|---|---|---|
| Battery_SOC | Modbus | % |
| PV1_Power | Modbus | kW |
| PV2_Power | Modbus | kW |
| Power_Bat1 | Modbus | W |
| Battery_Temperature | Modbus | °C |
| ReactivePower_Output_Total | Modbus | W |
| Inverter_Status | Modbus | <v.1> |
| PV1_Voltage | Modbus | V |
| PV2_Voltage | Modbus | V |
| PV_Generation_Today | Modbus | kW |
| PV_Generation_Total | Modbus | kW |
| ActivePower_Output_Total | Modbus | W |
| ActivePower_PV_Ext | Modbus | <v.1> |
| ActivePower_Load_Sys | Modbus | <v.1> |
| Energy_Purchase_Today | Modbus | kWh |
| Energy_Selling_Today | Modbus | kWh |
| ActivePower_PCC_Total | Modbus | Wh |
| ApparentPower_Output_Total | Modbus | <v.1> |
| ReactivePower_PCC_Total | Modbus | <v.1> |
| ApparentPower_PCC_Total | Modbus | <v.1> |
| Energy_Purchase_Total | Modbus | kWh |
| Energy_Selling_Total | Modbus | kWh |
| Bat_Charge_Total | Modbus | kWh |
| Bat_Discharge_Total | Modbus | kWh |
| Bat_Discharge_Today | Modbus | kWh |
| Load_Consumption_Total | Modbus | kWh |
| Load_Consumption_Today | Modbus | kWh |
| Bat_Charge_Today | Modbus | kWh |
| Active_Power_Load_Total | Modbus | <v.1> |
| ReactivePower_Load_Total | Modbus | <v.1> |
| ApparentPower_Load_Total | Modbus | <v.1> |
FAQ
No questions have been answered yet.
Questions and answers
Settings in Miniserver
OpenThank you for the Template fpr ZCS Azzuro HYD, could you explain, wich Settings must made in the miniserver to work with the template
1 reply
Hello, the setup is simple.
Simply import the template and enter the IP address of the logger with port 8899 under network peripherals.
Example: 192.168.0.2:8899
Thank you for your advice, but which Divice-ID are you using?
OpenWhich Divice-Id are you using? I tested ID 1, also 255, but without success, the connection doesnt send data.
1 reply
Hello, i use the Device-ID 1. Have you entered the correct IP address with its port?
Inverter HYD 6000 CON logger LSW3 USB
OpenI use a Usb wifi key on a single-phase Hyd 6000 hybrid inverter with Modbus id Rs485 equal to 6. We were trying to use this library by inserting the same index as the modbus rs485 or 1 but we do not obtain values on any register. If we query through the modbus rs485 it returns the values. The doubt arises as to which key is supported if USB or 232? Or can you give us indications
1 reply
Hello, i use the ZSM-ETH-USB Adapter with a 3 phase HYD 10000 inverter. I use the IP with Port 8899 and DeviceID 1. I can't tell you whether the Modbus protocols are the same for your inverter. You may have to try to find the Modbus protocols from the HYD 6000 inverter. Normally Azzurro inverters are rebranded Sofar Solar inverters.