ZCS Azzurro HYD 10000 ZSS/HYD 20000 ZSS - Three-Phase Hybrid Inverter - Modbus

by Michael RunggNo rating yet392 downloads

Content languageEnglish

Description

Template for the integration of an Azzurro 3-phase inverter with ZSM-ETH-EXT or ZSM-WIFI-EXT stick logger. The Modbus data is transmitted via the IP of the stick logger and port 8899.

Inputs and outputs · 31

NameTypeUnit
Battery_SOCModbus%
PV1_PowerModbuskW
PV2_PowerModbuskW
Power_Bat1ModbusW
Battery_TemperatureModbus°C
ReactivePower_Output_TotalModbusW
Inverter_StatusModbus<v.1>
PV1_VoltageModbusV
PV2_VoltageModbusV
PV_Generation_TodayModbuskW
PV_Generation_TotalModbuskW
ActivePower_Output_TotalModbusW
ActivePower_PV_ExtModbus<v.1>
ActivePower_Load_SysModbus<v.1>
Energy_Purchase_TodayModbuskWh
Energy_Selling_TodayModbuskWh
ActivePower_PCC_TotalModbusWh
ApparentPower_Output_TotalModbus<v.1>
ReactivePower_PCC_TotalModbus<v.1>
ApparentPower_PCC_TotalModbus<v.1>
Energy_Purchase_TotalModbuskWh
Energy_Selling_TotalModbuskWh
Bat_Charge_TotalModbuskWh
Bat_Discharge_TotalModbuskWh
Bat_Discharge_TodayModbuskWh
Load_Consumption_TotalModbuskWh
Load_Consumption_TodayModbuskWh
Bat_Charge_TodayModbuskWh
Active_Power_Load_TotalModbus<v.1>
ReactivePower_Load_TotalModbus<v.1>
ApparentPower_Load_TotalModbus<v.1>

FAQ

No questions have been answered yet.

Ratings and comments

No ratings or comments yet.

Questions and answers

  1. Settings in Miniserver

    Open

    Thank you for the Template fpr ZCS Azzuro HYD, could you explain, wich Settings must made in the miniserver to work with the template

    1 reply

    1. Hello, the setup is simple.

      Simply import the template and enter the IP address of the logger with port 8899 under network peripherals.

      Example: 192.168.0.2:8899

  2. Thank you for your advice, but which Divice-ID are you using?

    Open

    Which Divice-Id are you using? I tested ID 1, also 255, but without success, the connection doesnt send data.

    1 reply

    1. Hello, i use the Device-ID 1. Have you entered the correct IP address with its port?

  3. Inverter HYD 6000 CON logger LSW3 USB

    Open

    I use a Usb wifi key on a single-phase Hyd 6000 hybrid inverter with Modbus id Rs485 equal to 6. We were trying to use this library by inserting the same index as the modbus rs485 or 1 but we do not obtain values ​​on any register. If we query through the modbus rs485 it returns the values. The doubt arises as to which key is supported if USB or 232? Or can you give us indications

    1 reply

    1. Hello, i use the ZSM-ETH-USB Adapter with a 3 phase HYD 10000 inverter. I use the IP with Port 8899 and DeviceID 1. I can't tell you whether the Modbus protocols are the same for your inverter. You may have to try to find the Modbus protocols from the HYD 6000 inverter. Normally Azzurro inverters are rebranded Sofar Solar inverters.