Xvent
Content languageEnglish
Description
The energy class of the unit is A. The unit thus complies with most subsidy programs. Possibility of CO2 and RH sensor connection. The controls offers the possibility of extensi- on to remote control and connection to your smart home platform. Possibility of electronic bypass or mechanical bypass. Possibility of connecting external heating (up to 1 kW). The unit supplies power to the hea- ter only when it is running. Post-cooling func- tion after switching off the unit (3min)
Díky zařazení jednotky do energetické třídy A vyhovuje Xhouse dotačním pro- gramům (např. Nová zelená úsporám) K jednotce je možno dopojit CO2 a RH čidlo. Regulace dále nabízí možnost rozšíření pro vzdálené řízení a připojení na Váš chytrý dům. Možnost volby mezi elektronickým a me- chanickým bypassem.
Inputs and outputs · 53
| Name | Type | Unit |
|---|---|---|
| FW version | Modbus | <v> |
| act_state 1 | Modbus | <v> |
| act_state 2 | Modbus | <v> |
| act_state 3 | Modbus | <v> |
| AQS_state | Modbus | <v> |
| AQS_state.fan_flow | Modbus | m³/h |
| set_FAN_FLOW | Modbus | m³/h |
| act_PID.prop | Modbus | mV |
| act_PID.integ | Modbus | mV |
| act_PID.der | Modbus | mV |
| act_PID.result | Modbus | <v> |
| set_FAN_SPEED | Modbus | V |
| set_T_ROOM | Modbus | °C |
| act_CO2 | Modbus | ppm |
| act_RH | Modbus | %RH |
| act_Flow | Modbus | m³/h |
| act_T_ROOM | Modbus | <v> |
| act_T_EXHAUST | Modbus | <v> |
| FAN1.act_AO | Modbus | V |
| FAN1.act_tacho | Modbus | <v> |
| FAN2.act_AO | Modbus | V |
| FAN2.act_tacho | Modbus | <v> |
| timer.act_cool_preheat | Modbus | <v> |
| timer.act_cool_postheat | Modbus | <v> |
| timer.act_summer_mode | Modbus | <v> |
| timer.act_boost_mode | Modbus | <v> |
| timers_1 | Modbus | <v> |
| timers_2 | Modbus | <v> |
| act_FILTER_ELAPSED_TIME | Modbus | h |
| act_ui_timer | Modbus | <v> |
| act_preheat_timer High | Modbus | <v> |
| act_preheat_timer Low | Modbus | <v> |
| act_startup_timer | Modbus | <v> |
| rele | Modbus | <v> |
| front panel | Modbus | <v> |
| set_CO2 | Modbus | <v> |
| set_RH | Modbus | <v> |
| bits | Modbus | <v> |
| corr_T_ROOM | Modbus | <v> |
| set_BOOST_MODE_DURATION | Modbus | <v> |
| set_FILTER_LIFETIME | Modbus | <v> |
| set_SUMMER_MODE_DURATION | Modbus | <v> |
| front panel | Modbus | <v> |
| set_BOOST_MODE_DURATION | Modbus | <v> |
| set_SUMMER_MODE_DURATION | Modbus | <v> |
| set_CO2 | Modbus | <v.1> |
| set_RH | Modbus | <v.1> |
| bits | Modbus | <v.1> |
| corr_T_ROOM | Modbus | <v.1> |
| set_BOOST_MODE_FAN_SPEED | Modbus | <v.1> |
| set_BOOST_MODE_FAN_FLOW | Modbus | <v.1> |
| set_FAN_OFFSET_STATIC | Modbus | <v.1> |
| set_FILTER_LIFETIME | Modbus | <v.1> |