Template

whatwatt Go

by whattwatt AGNo rating yet292 downloads

Content languageEnglish

Description

The plugin simplifies the integration of whatwatt Go - Just adapt IP address in the URL field.

Exposed values (if supported/delivered by smart meter)

Use the building block "Bidirectional Meter" and connect the inputs/values "Power In Total [kW] = Consumption from Grid" and "Power Out Total [kW] = Delivery from PV into Grid", if you have PV, to Pf (Power or flow) and inputs/values "Energy In Total [kWh]" to Mrc and "Energy Out Total [kWh]" to Mrd, if you have PV - see picture.

Requriements

- whatwatt Go - Loxone Server

Inputs and outputs · 29

NameTypeCommandUnit
Power Out P3 [kW]VirtualInHttp\iinstantaneous_power\i\inegative\i\il3":\i\vkW
Power In Total [kW]VirtualInHttp\iinstantaneous_power\i\ipositive\i\itotal":\i\vkW
Current P2 [A]VirtualInHttp\i"current":\i\i"l2":\i\vA
Energy In Total [kWh]VirtualInHttp\ienergy\i\ipositive\i\itotal":\i\vkWh
Energy In Total T2 [kWh]VirtualInHttp\ienergy\i\ipositive\i\it2":\i\vkWh
Energy In Total T1 [kWh]VirtualInHttp\ienergy\i\ipositive\i\it1":\i\vkWh
Energy Out Total T1 [kWh]VirtualInHttp\ienergy\i\inegative\i\it1":\i\vkWh
Energy Out Total T2 [kWh]VirtualInHttp\ienergy\i\inegative\i\it2":\i\vkWh
Energy Out Total [kWh]VirtualInHttp\ienergy\i\inegative\i\itotal":\i\vkWh
Current P3 [A]VirtualInHttp\i"current":\i\i"l3":\i\vA
Power In P1 [kW]VirtualInHttp\iinstantaneous_power\i\ipositive\i\il1":\i\vkW
Power In P3 [kW]VirtualInHttp\iinstantaneous_power\i\ipositive\i\il3":\i\vkW
Power In P2 [kW]VirtualInHttp\iinstantaneous_power\i\ipositive\i\il2":\i\vkW
Power Out Total [kW]VirtualInHttp\iinstantaneous_power\i\inegative\i\itotal":\i\vkW
Power Out P1 [kW]VirtualInHttp\iinstantaneous_power\i\inegative\i\il1":\i\vkW
Power Out P2 [kW]VirtualInHttp\iinstantaneous_power\i\inegative\i\il2":\i\vkW
Current P1 [A]VirtualInHttp\i"current":\i\i"l1":\i\vA
Voltage P1 [V]VirtualInHttp\ivoltage\i\il1":\i\vV
Voltage P2 [V]VirtualInHttp\ivoltage\i\il2":\i\vV
Voltage P3 [V]VirtualInHttp\ivoltage\i\il3":\i\vV
IDVirtualInHttp\i"id":\i\v<v.0>
TariffVirtualInHttp\i"tariff":\i\v<v.0>
Conversion FactorVirtualInHttp\i"conv_factor":\i\v<v.3>
Reactive Energy In Total [kvarh]VirtualInHttp\ienergy\i\ireactive\i\ipositive\i\itotal":\i\vkvarh
Reactive Energy Out Total [kvarh]VirtualInHttp\ienergy\i\ireactive\i\inegative\i\itotal":\i\vkvarh
Power FactorVirtualInHttp\ipower_factor":\i\v<v.2>
Max Demand In Power Total [kW]VirtualInHttp\imax_demand\i\ipositive\i\itotal":\i\vkW
Max Demand In Power T1 [kW]VirtualInHttp\imax_demand\i\ipositive\i\it1":\i\vkW
Max Demand In Power T2 [kW]VirtualInHttp\imax_demand\i\ipositive\i\it2":\i\vkW