Template
whatwatt Go
Content languageEnglish
Description
The plugin simplifies the integration of whatwatt Go - Just adapt IP address in the URL field.
Exposed values (if supported/delivered by smart meter)
Use the building block "Bidirectional Meter" and connect the inputs/values "Power In Total [kW] = Consumption from Grid" and "Power Out Total [kW] = Delivery from PV into Grid", if you have PV, to Pf (Power or flow) and inputs/values "Energy In Total [kWh]" to Mrc and "Energy Out Total [kWh]" to Mrd, if you have PV - see picture.
Requriements
- whatwatt Go - Loxone Server
Inputs and outputs · 29
| Name | Type | Command | Unit |
|---|---|---|---|
| Power Out P3 [kW] | VirtualInHttp | \iinstantaneous_power\i\inegative\i\il3":\i\v | kW |
| Power In Total [kW] | VirtualInHttp | \iinstantaneous_power\i\ipositive\i\itotal":\i\v | kW |
| Current P2 [A] | VirtualInHttp | \i"current":\i\i"l2":\i\v | A |
| Energy In Total [kWh] | VirtualInHttp | \ienergy\i\ipositive\i\itotal":\i\v | kWh |
| Energy In Total T2 [kWh] | VirtualInHttp | \ienergy\i\ipositive\i\it2":\i\v | kWh |
| Energy In Total T1 [kWh] | VirtualInHttp | \ienergy\i\ipositive\i\it1":\i\v | kWh |
| Energy Out Total T1 [kWh] | VirtualInHttp | \ienergy\i\inegative\i\it1":\i\v | kWh |
| Energy Out Total T2 [kWh] | VirtualInHttp | \ienergy\i\inegative\i\it2":\i\v | kWh |
| Energy Out Total [kWh] | VirtualInHttp | \ienergy\i\inegative\i\itotal":\i\v | kWh |
| Current P3 [A] | VirtualInHttp | \i"current":\i\i"l3":\i\v | A |
| Power In P1 [kW] | VirtualInHttp | \iinstantaneous_power\i\ipositive\i\il1":\i\v | kW |
| Power In P3 [kW] | VirtualInHttp | \iinstantaneous_power\i\ipositive\i\il3":\i\v | kW |
| Power In P2 [kW] | VirtualInHttp | \iinstantaneous_power\i\ipositive\i\il2":\i\v | kW |
| Power Out Total [kW] | VirtualInHttp | \iinstantaneous_power\i\inegative\i\itotal":\i\v | kW |
| Power Out P1 [kW] | VirtualInHttp | \iinstantaneous_power\i\inegative\i\il1":\i\v | kW |
| Power Out P2 [kW] | VirtualInHttp | \iinstantaneous_power\i\inegative\i\il2":\i\v | kW |
| Current P1 [A] | VirtualInHttp | \i"current":\i\i"l1":\i\v | A |
| Voltage P1 [V] | VirtualInHttp | \ivoltage\i\il1":\i\v | V |
| Voltage P2 [V] | VirtualInHttp | \ivoltage\i\il2":\i\v | V |
| Voltage P3 [V] | VirtualInHttp | \ivoltage\i\il3":\i\v | V |
| ID | VirtualInHttp | \i"id":\i\v | <v.0> |
| Tariff | VirtualInHttp | \i"tariff":\i\v | <v.0> |
| Conversion Factor | VirtualInHttp | \i"conv_factor":\i\v | <v.3> |
| Reactive Energy In Total [kvarh] | VirtualInHttp | \ienergy\i\ireactive\i\ipositive\i\itotal":\i\v | kvarh |
| Reactive Energy Out Total [kvarh] | VirtualInHttp | \ienergy\i\ireactive\i\inegative\i\itotal":\i\v | kvarh |
| Power Factor | VirtualInHttp | \ipower_factor":\i\v | <v.2> |
| Max Demand In Power Total [kW] | VirtualInHttp | \imax_demand\i\ipositive\i\itotal":\i\v | kW |
| Max Demand In Power T1 [kW] | VirtualInHttp | \imax_demand\i\ipositive\i\it1":\i\v | kW |
| Max Demand In Power T2 [kW] | VirtualInHttp | \imax_demand\i\ipositive\i\it2":\i\v | kW |