Victron Cerbo GX

by DARIUSZ STOKLOSANo rating yet872 downloads

Content languageEnglish

Description

This template was created based on the file: CCGX-modbus-tcp-registry from Victron. From this template, you can start building your backup battery system. I use it for monitoring power consumption from the grid and battery.

Inputs and outputs · 22

NameTypeUnit
Grid L1Modbus<v.1>
Grid L2Modbus<v.1>
Grid L3Modbus<v.1>
PV - AC-coupled on output L1Modbus<v.1>
AC Consumption L1Modbus<v.1>
Battery State of Charge (System)Modbus<v.1>
PV - AC-coupled on output L2Modbus<v.1>
PV - AC-coupled on output L3Modbus<v.1>
AC Consumption L1Modbus<v.1>
AC Consumption L2Modbus<v.1>
AC Consumption L3Modbus<v.1>
Genset L1Modbus<v.1>
Battery Voltage (System)Modbus<v>
Charger powerModbus<v.1>
DC System PowerModbus<v.1>
Power between meter and inverter/charger, L1Modbus<v.1>
Power between meter and inverter/charger, L2Modbus<v.1>
Power between meter and inverter/charger, L3Modbus<v.1>
L1 PowerModbus<v.1>
Battery PowerModbus<v.1>
Relay 1 statusModbus<v>
Relay 2 statusModbus<v.1>

FAQ

No questions have been answered yet.

Ratings and comments

No ratings or comments yet.

Questions and answers

  1. Modbus or Ethernet?

    Open

    Hi,

    Interesting to see fit Victron Cerbo GX library, thanks for work. I have question, really need modbusTCP Loxone extention or can I use standard ethernet for communication?

    Marek

    1 reply

    1. Hi Marek, you do not need modbusTCP extension. You simple go to network peripherals -> Add new network device ->> Server Modbus ->> and put IP cerbo gx

  2. sensor for AC Out 1 Power

    Open

    Hi, thank you for the template. I tried to add an analog Sensor for AC Out (1) Power (= Critical Loads), but can‘t get valid data.

    Looking at the xls table, it seems to be 23, 4516 or 878, but none of them works. Addresses 23 & 4516 result in a Modbus error. 878 does return a value, but what should 6225920.0 be, for example, when the VRM displays approximately 90W at critical load?

    How can I convert the value to watts? Any idea?

    regards, Wolfgang

    2 replies

    1. Hi Wolfgang, I checked now and the registry: 878, 880, 882 working fine in my. I checked how I have set the sensor and this is it: Comand: 4 - Read input Registry (0x04) Data type: 32 bit Single Integer 16 bit registry - check Registry order - check

      For me, those settings working and I see this same value in VRM and loxone for Critilac loads

    2. thank you very much, i missed „Registry order - check“