ThermannPro Heat Pump
Content languageEnglish
Description
Power units from 6kW to 24kW with the option of connecting to a cascade. The use of components from renowned manufacturers, including EVI technology, which allows the units to operate down to -25°C with a water outlet temperature of up to 55°C. Equithermal control as standard. Modbus RTU - disconnect the control display and connect the Loxone Modbus extension instead. A – green wire, B – yellow wire, isolate red and black wire. Modbus TCP/IP - the Thermann Pro converter must be ordered, which connects to COM2 instead of the IOT module. The IOT module must be connected to the output of the converter in order to comply with the terms of the warranty. With this, you can control the heat pump with the control display and the Loxone at the same time.
The template includes the possibility of changing modes, setting desired temperatures and heating curves. When heating curves are selected, the manually set temperature will be blocked and the pump is already controlled according to heating curves depending on the outside temperature. The heat pump can also be controlled in the schematic diagram.
Mode setting: 1. OFF 2. Heating 3. DHW 4. Heating + DHW 5. Floorheating 6. Floorheating + DHW 7. Cooling 8. Cooling + DHW
Set Temp: 1. Heating 2. Floor Heating 3. Cooling 4. Hot Water
Set Curve: 1. Heating 2. Floor Heating 3. Cooling 4. Hot Water
Inputs and outputs · 25
| Name | Type | Unit |
|---|---|---|
| Temp. Set-Heating | Modbus | °C |
| Switching on/off | Modbus | <v> |
| Mode setting | Modbus | <v> |
| Temp. Set-Floor Heating | Modbus | °C |
| Temp. Set-Hot Water | Modbus | °C |
| Temp. Set-Cooling | Modbus | °C |
| Cooling setting curve | Modbus | <v> |
| Heating setting curve | Modbus | <v> |
| DHW setting curve | Modbus | <v> |
| Floorheating setting curve | Modbus | <v> |
| DHW temp T16 | Modbus | °C |
| Buffer tank temp T10 | Modbus | °C |
| External ambient temp | Modbus | °C |
| T8 | Modbus | °C |
| T15 | Modbus | °C |
| Temp. Set-Heating | Modbus | °C |
| Switching on/off | Modbus | <v> |
| Mode setting | Modbus | <v> |
| Temp. Set-Cooling | Modbus | °C |
| Temp. Set-Floor Heating | Modbus | °C |
| Temp. Set-Hot Water | Modbus | °C |
| Cooling setting curve | Modbus | <v> |
| Floorheating setting curve | Modbus | <v> |
| DHW setting curve | Modbus | <v> |
| Heating setting curve | Modbus | <v> |