Systemair SAVE VTR
Content languageEnglish
Description
Control SAVE VTR500 and similar systems from Systemair.
New Systemair controls have standard and readily available Modbus/RTU over three-wire (A, B and GND) RS485 on the Connection Board.
Slave address: 1 to 247, Baud rate: 9600 to 115200, Parity: None, Even, Odd, Stop bits: 1 (fixed)
Inputs and outputs · 17
| Name | Type | Unit |
|---|---|---|
| REG_USERMODE_MODE | Modbus | <v.1> |
| REG_SENSOR_SAT | Modbus | ° |
| REG_SENSOR_RHS_PDM | Modbus | % |
| REG_SENSOR_PDM_EAT_VALUE | Modbus | ° |
| REG_OUTPUT_SAF | Modbus | o/min |
| REG_OUTPUT_EAF | Modbus | o/min |
| REG_OUTPUT_ALARM | Modbus | <v.1> |
| REG_SENSOR_OAT | Modbus | ° |
| REG_HEAT_EXCHANGER_FROM_SATC | Modbus | % |
| REG_OUTPUT_Y2_ANALOG | Modbus | W |
| REG_OUTPUT_Y2_DIGITAL | Modbus | <v.1> |
| REG_FILTER_REMAINING_TIME | Modbus | <v.1> |
| REG_FILTER_REMAINING_TIME | Modbus | <v.1> |
| REG_TC_SP | Modbus | <v.1> |
| REG_USERMODE_HMI_CHANGE_REQUEST | Modbus | <v.1> |
| REG_USERMODE_MANUAL_AIRFLOW_ LEVEL_SAF | Modbus | <v.1> |
| REG_USERMODE_MANUAL_AIRFLOW_ LEVEL_EAF | Modbus | <v.1> |
FAQ
No questions have been answered yet.
Questions and answers
Integration of systemair into loxone
OpenI would like to integrate my systemair sace vtr 250/B into my loxone home automation. Do you have any template how to steer fan speed etc. over the loxone app? Thanks!
1 reply
Do you have the Loxone modbus module? If Yes, I guess you can use the same template and just check the modbus adress for your 250/B.
Br eirik
Request for SAVE VTR 300 L Modbus registers – Freecooling / Rotor stop logic
OpenHi, I am currently using your Loxone integration map for my Systemair SAVE VTR 300 L recuperation unit. It works great for basic control (fan speeds, temperature readings), but I would like to expand it to support the freecooling feature (using cool outdoor air in summer by stopping the rotary heat exchanger). Since the VTR 300 L uses a rotary wheel instead of a physical bypass flap, the cooling mode is achieved by completely stopping the rotor. Could you please advise me on how to best implement this into the Loxone config, or point me to the right Modbus registers? Specifically, I'm looking for: The recommended approach: Is it better to let the Systemair internal logic handle it automatically by simply lowering the supply air temperature Setpoint (e.g., to 16°C) from Loxone during summer nights? If so, is there a specific register to enable/disable the freecooling function itself? Direct control: If I want to trigger the rotor stop manually via Loxone logic, which Modbus registers (holding/input) control the freecooling state or allow overriding the rotor speed to 0? If you have an updated Modbus register map for the SAVE series or a snippet of your Loxone config handling this, it would be a massive help. Thank you so much for your time and for creating the integration map! Best regards, Tomas Pojar. +420775863744
1 reply
To determine which API should be used, I need to know which software version your SAVE VTR 300 L is running.
You can find this under System Information → Unit Version (or System Information → Aggregat Version, depending on your language settings).
Once I know the software version, I can advise which API and Modbus register map to use.