Sunways STH Modbus RTU
Content languageEnglish
Description
ModBus template for reading values from Sunways STH inverter over RTU.
Inputs and outputs · 50
| Name | Type | Unit |
|---|---|---|
| Total Grid-Injection Energy on Meter | Modbus | kWh |
| Phase A Power on Meter | Modbus | W |
| Phase B Power on Meter | Modbus | W |
| Phase C Power on Meter | Modbus | W |
| Total Power on Meter | Modbus | W |
| PV Input Total Power | Modbus | W |
| Battery Power | Modbus | W |
| Battery SOC | Modbus | % |
| Inverter Running Status Value | Modbus | <v> |
| Total Purchasing Energy from Grid on Meter | Modbus | kWh |
| Current Load Power | Modbus | W |
| Total PV Generation on that day | Modbus | kWh |
| Temperature Sensor 1 | Modbus | °C |
| Temperature Sensor 2 | Modbus | °C |
| Temperature Sensor 3 | Modbus | °C |
| PV1 Voltage | Modbus | V |
| PV1 Current | Modbus | A |
| PV2 Voltage | Modbus | V |
| PV2 Current | Modbus | A |
| PV1 Input Power | Modbus | W |
| PV2 Input Power | Modbus | W |
| PV Generation Energy on that day | Modbus | kWh |
| Total PV Generation from Installation | Modbus | kWh |
| Total PV Generation Time from Installation | Modbus | H |
| Grid Injection Energy on that day[Meter] | Modbus | kWh |
| Grid Purchasing Energy on that day[Meter] | Modbus | kWh |
| Backup Output Energy on that day | Modbus | kWh |
| Battery Charge Energy on that day | Modbus | kWh |
| Battery Discharge Energy on that day | Modbus | kWh |
| Loading Energy on that day | Modbus | kWh |
| Energy Purchased from Grid on that day | Modbus | kWh |
| Total Energy injected to grid | Modbus | kWh |
| Total Energy Purchased from Grid from Meter | Modbus | kWh |
| Total Output Energy on backup port | Modbus | kWh |
| Total Energy Charged to Battery | Modbus | kWh |
| Total Energy Discharged from Battery | Modbus | kWh |
| Total PV Generation | Modbus | kWh |
| Total Loading Energy consumed at grid side | Modbus | kWh |
| Total Energy Purchased from Grid at inverter side | Modbus | kWh |
| Battery DC Voltage | Modbus | V |
| Battery DC Current | Modbus | A |
| Battery Mode Value | Modbus | <v> |
| BMS Charge Imax | Modbus | A |
| BMS Discharge Imax | Modbus | A |
| Battery SOH | Modbus | % |
| BMS Status | Modbus | <v> |
| BMS Pack Temperature | Modbus | °C |
| Cell Temperature Max | Modbus | °C |
| Cell Temperature Min | Modbus | °C |
| Working Mode Value | Modbus | <v> |
FAQ
No questions have been answered yet.
Questions and answers
Numbers of energy
OpenHi, thanks for this library. I have small question. After implementing in Loxone, numbers from STH are quite big. Meters are on GW of energy, instead of kW. Did you have the same trouble with that? If yes, what was the solution?
Thanks, Vaclav
1 reply
Hi Václav,
I did not have this problem. I just checked the modbus gives KW for me eg for "Battery Power". I just divide it by 1000 to get W and connecting that to Meter block after that.
Regards, László
Log in to rate, comment or ask a question. Log in