Sungrow New Hybrid 2024 SH15-25T Modbus RTU
Content languageEnglish
Description
Connection to Modbus RTU (485) inverter interface.
Connection Sungrow Com2 connector A1+B1 (data logger connection).
Attention not for Modbus TCP Winet S2.
A few values such as mains connection and total DC are on other registers.
MPPT 3 can now be read out and running state for battery charge and discharge can be read out.
Unfortunately, these values cannot be read via Winet S2 and Modbus TCP with the current Sungrow firmware.
FAQ
No questions have been answered yet.
Questions and answers
Charging with Loxone. RTU actuators
OpenHello is there a way to control the actuators? At the moment I can only see the sensors and can display the data, but it is not possible to build intelligent solutions with dynamic electricity tariffs?
3 replies
Hello Mr. Altmann, currently the control via Modbus is not entered into the program. We are currently clarifying the data points for control with Sungrow and hope that we can adapt the module. If you already have data points, you are welcome to send them to us for incorporation.
unfortunately i don´t have the data points Currently i am facing another problem. The sensor "Batterie Leistung" always show a positive value, so the Loxone "Speicher Zähler" doesnt know if the battery is charging or discharging, do you have a solution for that?
Maybe this PDF helps? https://github.com/BigWanna/Sungrow-ModbusRegister-/files/13242230/TI_20231019_Communication.Protocol.of.Residential.Hybrid.Inverter_V1.1.2_EN.pdf
Control inverter
OpenHello. Is there anything new in this case? Will it be possible to control the inverter?
No replies
Modbus TCP Is avaliable now 08.12.2025!
OpenThanks to an update to the inverter and the Winet-S2, Modbus TCP is now available again.
1 reply
Can you send some details on how it works?
Leistung Netz
OpenHi, what does "Leistung Netz" deliver? In my config there are 375 MW of flow displayed instead of the correct 1 kW that is flowing. Why is that so?
No replies
Leistung Netz
OpenHallo!!! Eine Frage: Leistung Netz soll doch der Wert sein, den er in das Netz zurückgibt und mit dem Hauptzähler verbunden ist?? Leider liefeet der ganz komische Werte. Ist das bei jeden so??? Und musstet noch jemand mppt /1000 rechnen um auf einen vernünftigen Wert zukommen?? Danke
No replies