SUNGROW Hybrid Inverter
Content languageEnglish
Description
Read out the values of your SUNGROW hybrid inverter via the Modbus protocol.
Inputs and outputs · 14
| Name | Type | Unit |
|---|---|---|
| Total Output Energy | Modbus | kWh |
| Total DC power | Modbus | kW |
| Total PV Generation | Modbus | kWh |
| Total Export Energy from PV | Modbus | kWh |
| Total direct energy consumption | Modbus | kWh |
| Battery power | Modbus | kW |
| Battery state of healthy | Modbus | % |
| Self-consumption of today in percent | Modbus | % |
| Total active power | Modbus | kW |
| Total Import Energy | Modbus | kWh |
| Total Export Energy | Modbus | kWh |
| Battery level | Modbus | % |
| Running state | Modbus | <v.1> |
| Export Power | Modbus | kW |
FAQ
No questions have been answered yet.
Questions and answers
Example is wrong
OpenWe use IO 13021 on Spwr. This is an unsigned integer. Battery is always discharging. IO 13000 gives charging/discharging (Appendix 1.2), use a Binary Decoder. Feel free to contact me or Christoph Pfoser.
No replies
Battery power
Opender wert kommt nu als positiver wert. wie kann ich erkennen ob die batterie lädt oder entlädt?
1 reply
wenn das stimmt, was hier und im Sungrow Dokument steht, dann musst du den Running State mit einem Binärdekoder verknüpfen, das 2. Bit auslesen (steht für charging, oder das 3. Bit für disharging), mit -2 (o. +2) multiplizieren, +1 addieren (o. substrahieren). Das ergibt dir dann eine -1 für den Fall wenn die Batterie geladen wird und +1 für alle andere Fälle. Diesen Wert multiplizierst du mit Battery Power.
Battery Power
OpenWarum kann man nicht einfach die Vorlage anpassen? Wichtig ist auch zu wissen, dass man den IO13000 nur über die 2. Buchse vom WR bekommt. Könnte man in die Anleitung packen und somit Supportkraft einsparen....
3 replies
was heißt das, die 2. Buchse??? Ich habe einen Ethernet Dongle dran.
Hinter dem Dongle ist noch eine Schnittstelle
in der Tat, die "normale" LAN Schnittstelle. Aber die ist nur für TCP Modbus, man muss danach noch immer den Inverter über den Dongle (WIFI oder LAN) mit dem Internet verbinden um die Verbindung zu isolarcloud herzustellen. Wer hat sich denn das überlegt???? Aber jetzt wird dafür der Running State richtig ausgegeben.
IO Adressen um 1 niedriger als im Dokument
OpenSoeben wurde der SH10RT in Betrieb genommen.
Warum sind in dem Template die IO Adressen um 1 niedriger als im Dokument von Sungrow angegeben???? Gibt es schon ein neuers Dokument von Sungrow?
z.B. "Battery Level" hat im Template eine IO Adresse von 13022 aber im Dokument eine IO Adresse von 13023?!
Kenn mich nicht aus .....
Danke für die Hilfe
2 replies
Hier ein Link zu der Auflistung aller Modbusbefehle mit einer kurzen Erklärung und der tatsächlich zu verwendenden Adressen: https://gist.github.com/dnoegel/543c72ef722365a3934bbad0bb43e222
habe die Antwort auf meine ursprüngliche Frage im Sungrow Dokument selbst gefunden auf Seite 22, gut versteckt:
Note: Communication address = protocol address – 1. If data of address 5000 is to be inquired, the corresponding sending address data is 4999 (0x1387);
Ppwr configured wrong in "Sungrow Hybrid Example"
OpenIn my configuration i had to change the Ppwr input. In the example the "Total active power" is connected to Ppwr (this includes also the power from the grid) I had to change it to Total DC power, to see what is produced.
https://i.imgur.com/AdncNRI.png
No replies
From Modbus Protocol I can control the discharge et charge par Loxone (modbus)
OpenRegistre 13050 - EMS mode: 2 (Forced mode) Registre 13051 - Charge/discharge command : =0xAA Charge OU 0xBB Discharge OU 0xCC Stop Registre 13052 - Power : 0-5000W Can you confirme it? Thanks
No replies
Battarie mit Spot Optimierer
OpenGuten Tag Wie kann ich befehle schicken damit Batterie geladen wird weil Strom jetzt günstig von Netz gibt's?? Gibt es ein Modbus Befehl für Batterie??
No replies
Seit letzem Loxone Update kommen die Werte von Batterie Laden falsch an
OpenHallo Loxone Team, ich habe seit dem letzen Update das Problem das wennd er Akku geladen wird, die Werte vom Modbus falsch ausgegeben werden.Kennt jemand da schon eine Lösung dafür?
No replies
Sind die neuen SH10T und SH20T sowie SBH kompatibel?
OpenHallo Loxone Team,
können die neuen Hybrid Wechselrichter SH..T Serien über die Modbus Schnittstelle ausgelesen werden? Gibt es hier aktuelle Adresstabellen?
1 reply
Dies würde mich auch interessieren, auch in Kombination mit den neuen SBH Speichern wie z.B. SBH250.
SH25T
OpenHi, i've installed the new Sungrow SH25T, does it work with it?
2 replies
Hello it is not in the supported list so I am unable to confirm this but on the library there is a template for your time of investor available https://library.loxone.com/detail/-923/support; this should work for your device.
i'd like to use Modbus TCP, the other template is for Modbus RTU :-(. but thank you
Log in to rate, comment or ask a question. Log in