Connection Guidance

1. Requirements Inverter: Solinteg IntegM Series Hybrid Inverter (MHS3-8K, MHT4-20K, MHT25-50K) Miniserver: Miniserver, Miniserver Compact, Miniserver Go (Either one of them) Software: Loxone and Loxone Config (Please download them from Loxone official website.) Documents: Solinteg Modbus Register Table (Please contact Solinteg Academy at [email protected] for document application)

2. Wire connection As the communication protocol between the Solinteg inverter and the Miniserver is Modbus TCP, please use the LAN module or DUOCOM to connect the inverter to the network, seen as below.

Note: Please connect the network cable to the RJ45 port of the LAN/DuoCom module, as shown in the following pictures.

3. Loxone Configuration

Step1: Please open the ‘Loxone Config’ tool and connect your miniserver. (For how to connect the miniserver please refer to the miniserver user manual or ask for help from Loxone.)

Step2: Download the Loxone template file of Solinteg inverter form Loxone library.

Step3: Open the template file, seen as below:

Step4: Click the Modbus server and enter the IP address of the inverter, seen as the above picture. You can get the inverter IP address by IP tools or check it on the inverter screen, please refer to the following picture.

Note: If you cannot get the right IP address of the inverter, you can use the IP tools to distribute a fixed IP address to the inverter.

Step5: Click the Solinteg Inverter and enter the modbus inverter address 255, seen as below. It is fixed to 255.

Step 6: Save the template to your miniserver, and then you can open the Loxone to check.

Open Loxone:

Template effect:

Tips: You can also edit the Loxone config file according to your preference, such as add the voltage, current or other parameters to your monitor. Just pull the sensors into the editor or add more sensors as you like, and edit the parameters according to the Solinteg Modbus protocol, seen as below.

Inputs and outputs · 7

NameTypeUnit
Battery SOCModbus%
Power - BatteryModbuskW
Input Power - PV1ModbuskW
Input Power - PV2ModbuskW
Input Power - PV3Modbus<v.1>
Grid PowerModbuskW
Input Power - PV4ModbuskW