With this Template, you can Control your Sentiotec Sauna with Loxone.

The RS485 interface allows sauna control units in the Professional Series (Pro-B2, Pro-B3, Pro-C2, Pro-C3) to be connected to a domestic bus system, which allows the sauna heater and the infrared emitter to be started remotely. When implementing this connection, the specifications in EN 60335-1 and EN 60335-2-53 must be adhered to.

EN 60335-2-53 specifies safety equipment and safety measures for sauna heaters and infrared emitters that can be started remotely.

Examples of this safety equipment include:

● The sauna heater, which is connected to a sauna control unit from the Professional Series and can be started remotely using a domestic bus system, must satisfy the cover test in accordance with paragraph 19.101 of EN 60335-2-53.

● Alternatively, a safety shut-off device can be installed above the sauna heater. This safety shut-off device must guarantee that the sauna heater switches off as soon as an object is placed on it, thereby ensuring that the sauna heater satisfies the cover test in accordance with paragraph 19.101 of EN 60335-2-53.

● If an infrared emitter is connected to a sauna control unit from the Professional Series and can be started remotely using a domestic bus system, the door of the cabin must be fitted with an interlock such that the stand-by mode setting for remote operation is disabled, if the cabin door is opened when the stand-by mode setting for remote operation is set.

Descriptions of the control and integration via RS 485 for the sauna controls are in the following links:

https://www.sentiotec.com/sentiotec/sentiotec-sauna/steuerungen/rs485/rs485_01-21_1-027-269_de-en-fr.pdf

https://www.sentiotec.com/sentiotec/sentiotec-sauna/steuerungen/professional_d2/d_12-20_1-041-284_en-de-fr-it-nl-sv-fi-ru.pdf

Inputs and outputs · 10

NameTypeCommandUnit
Temperature BenchComm\TEMP-BENCH \v°C
Temperature HeaterComm\TEMP-HEATER \v°C
Sauna Status OffComm\SAUNA off
Sauna Status OnComm\SAUNA on
Call Bench TemperatureCommget temp-bench val\r\n
Call Heater TemperatureCommget temp-heater val\r\n
Call Sauna StatusCommget sauna \r\n
Call Sauna OffCommset sauna off\r\n
Call Sauna OnCommset sauna on\r\n
Target temperature SaunaCommset sauna val <v>\r\n<v.1>