Skip to content
Image of Sensibo Sky
Template

Sensibo Sky

by Ekspertni sigurnosni sustavi d.o.o.No rating yet506 downloads

Content languageEnglish

Description

The Sensibo Sky works with over 10,000 different AC brands. As long as your AC unit uses a remote control, the Sensibo Sky should be compatible with your unit.

Inputs and outputs · 1

NameTypeCommandUnit
Command VCQ1VirtualOut/api/v2/pods/evAeFtMz/acStates?apiKey=69QXhrsR1oUBCkFwk6MZMVcuALczdl

FAQ

No questions have been answered yet.

Ratings and comments

No ratings or comments yet.

Questions and answers

  1. Error with HTTP/1.1 400 BAD_REQUEST

    Open

    Hi,

    I followed your instruction by finding:

    “YOUR API” – your created API from website

    “YOUR PODS“ – is UID from „Advance Info” of your devices.

    I imported the "Sensibo sky Loxone template" (1.1.2 - 17.02.2023)

    Then replace “YOUR API” and “YOUR PODS“ in the original command /api/v2/pods/"YOUR PODS"/acStates?apiKey="YOUR SENSIBO API"

    I removed the quotation marks on both sides of YOUR API and YOUR PODS.

    But when the miniserver is sending a command: (In this case have removed my API and PODS

    73 21:19:37.732 miniserver Request home.sensibo.com /api/v2/pods/“YOUR API”/acStates?apiKey="YOUR SENSIBO API" GET /api/v2/pods/“YOUR API”/acStates?apiKey="YOUR SENSIBO API" HTTP/1.1

    Host: home.sensibo.com

    User-Agent: [en]

    Content-Type: text/xml; charset=utf-8

    Connection: close

    {"acState": {"on": ,"mode": "","fanLevel": "","targetTemperature": 0,"temperatureUnit": "C","swing": "stopped"}}

    then I get the response below: (In this case have removed my API and PODS)

    Response home.sensibo.com /api/v2/pods/“YOUR API”/acStates?apiKey="YOUR SENSIBO API" HTTP/1.1 400 BAD_REQUEST

    Content-Length: 0

    Connection: Close

    Do you have any suggestions on what is wrong?

    I run on miniserver go. gen 1 and located in Norway

    2 replies

    1. Hello, I have the same error I have the commands from the page: https://sensibo.github.io enter the GET commands work but the commands to turn on ac do not work. Does it still work with the creator?

    2. With some testing with the swagger tool. https://editor.swagger.io/

      Then I found out that the issue I had was actually that the mode "auto" didn't exist. So when I changed away from that mode, it worked. I have not solved the part that the "auto" mode doesn't work, but anyhow. Progress.

  2. Not working + solution

    Open

    Hi there, I tried your guide but it didn't work. But after changing the method of the Virtual Output Command to post, it worked! How? Simply change 'GET' to 'POST' in the field 'HTTP Method for ON' and move '<v>' from the 'HTTP header for On' to 'HTTP body for on'. Cheers!

    1 reply

    1. You saved my day. Thank you very much. :-)