Template

Samsung Heating & Cooling

by LOXONEBrand: SamsungNo rating yet672 downloads

Content languageEnglish

Description

This template allows you to control your Samsung Heatpump via the [Modbus Interface Module MIM-B19N / MIM-B19NT] over Modbus RTU. From Loxone there here is a Modbus Extension required. It is also possible to integrate the Samsung heat pump via Modbus Air as a wirelessly variant.


The choice of paring Samsung Heatpumps with Loxone offers the possibility of:

- integrating demand-based heating and cooling depending on e.g. presence or the protection of open windows - Interaction with the blinds for saving effects by passive cooling thanks to Loxone automatic shading - Active integration in interaction with e.g. PV- systems in a Loxone Energy Management - Using flexible electricity tariffs with the Spot Price Optimizer. - Use statistics ore individual notifications - Create your own individual schematics - Reduce cycles and operating hours of your Samsung device - Combining hybrid solutions e.g. Heatpump and PV- Heating element in your Hot Water Storage - Create e.g. yearly operation goals like certain annual runtime forces for hybrid systems e.g. (Heatpump 60% amount of energy, Gas heater 40% amount of energy) to fulfill the requirements of your local government. - Grid management according to §14a ENWG in Germany - In addition to the electrical power, the current and total thermal energy can also be visualized via the Loxone Energy Flow Monitor. To the compact overview for e.g. contractors. - Influence on the hot water circulation pump by controlling via the presence detectors. - Increased security through leakage detection or activation of IP cameras in the plant room.


Structure:


Samsung helpcenter and download area:

- Before purchasing the "Modbus Interface Module MIM-B19N / MIM-B19NT" for your heating & cooling operation system, please check the compatibility with your Samsung partner or Samsung purchaser. You can compare the designations with on your Samsung type label. - If you need help how to deal with the integration of the "MIM-B19N / MIM-B19NT" or need general information, please use the Samsung attached download area. Unfortunately, Samsung does not have an international download area for heatpumps. Therefore, the documentation must always be checked for the latest version with the partner or seller. - The assembly and initial commissioning of the "MIM-B19N / MIM-B19NT" Modbus module are described in the following explanatory video:


With our step by step manual for collecting the heating or cooling demand and forwarding it to the Samsung heatpump, we enable the interaction of the individual room control with the central heating/cooling system of Samsung. Please take a look on the Loxone Config sample file in the Library download area.


UseCase: Integration of a Samsung EHS Mono HT Quiet: Residential building with heating, cooling, heat buffer, warm water storage and heating circuits.

- Device Air/Water EHS Mono HT Quiet - Heat buffer tank - Warm water storage tank --> Controlled by Loxone - Direct circuit HC1 --> Controlled by Loxone - Mixing circuit heating/cooling HC2 (e.g. ceiling heating/cooling) --> Controlled by Loxone

Please note that the Samsung Heatpump is not able to use more than two HC´s. In This case the HC3 or more has to be wired to Loxone.

Inputs and outputs · 36

NameTypeUnit
State HeatpumpModbus<v>
State Supply flow target temperature HC1ModbusºC
State Room target temperature HC1Modbusº C
State Heatpump modeModbus<v>
Actual Hot water temperatureModbus°C
State Hot water target temperatureModbus°C
Actual Outside temperatureModbus°C
State Hot water operation modeModbus<v>
State Hot water operationModbus<v>
Actual Back flow temperatureModbus° C
Actual Supply flow temperature HC1Modbus°C
State Switching valveModbus<v>
State Backup HeaterModbus<v>
State Booster HeaterModbus<v>
Actual Water flow l/mModbusl/m
State Supply flow target temperature HC2Modbus°C
State operation HC2Modbus<v.1>
State Room target temperature HC2Modbus°C
Set State HeatpumpModbus<v.1>
Set Heatpump modeModbus<v.1>
Set Target Supply Flow target temperature HC1Modbus°C
Set Hot water operationModbus<v.1>
Set Hot water target temperatureModbus<v.1>
Set Hot water operation modeModbus<v.1>
Set ID Outside TemperatureModbus<v.1>
Set ID Compressor FrequencyModbus<v.1>
Set Operation HC2Modbus<v>
Set Target Supply Flow temperature HC2Modbus°C
Set Target Room temperature HC2Modbus°C
Set ID Operation HC2Modbus<v.1>
Set ID Target Supply Flow temperature HC2Modbus<v.1>
Set ID Target Room temperature HC2Modbus<v.1>
Set ID Additional Heater Hot WaterModbus<v.1>
Set ID Additional Heater Heat/Cool BufferModbus<v.1>
Set ID Flow RateModbus<v.1>
Set ID Switching ValveModbus<v.1>

FAQ

No questions have been answered yet.

Ratings and comments

No ratings or comments yet.

Questions and answers

  1. Can you please add the register to receive error messages from the heat pump

    Open

    Hi,

    can you please add the modbus register (I think it is 76 and / or 77) to your config file, so that Loxone is receiving an error if the heating pump has any error.

    I am not sure how to convert the decimal error code into a number: Error information collected by MCC in bit#

    Many thanks Markus

    No replies

  2. Video installing MIM-B19N for Samsung EHS heat pump

    Open

    Hi, I would like kindly to ask you for support. I do the integration for the first time for myself, and I like to see the video, on which I need your approval to see. Also I want to ask if there is a need to change the setting on modbus MIM-B19N module, when I am going to connect it into Loxone Modbus Air or if the module will work after connection to modbus air and heat pump without its setting change.

    Thanks a lot,

    Best regards,

    Jiri

    No replies

  3. Modbus Air power supply

    Open

    Hello, Can I tap the power supply for the Modbus Air module from the 12V supply from the main board (CN12)? Or should I put a separate power supply here? Thank you for your help.

    1 reply

    1. Please consult Samsung directly on that regard. Modbus Air consumes only little power thanks to Air, see our datasheet for reference.