Template
S & P DOMEO 210 RD
Content languageEnglish
Description
Control of a heat exchanger of the S & P brand through the modbus RTU protocol
Inputs and outputs · 76
| Name | Type | Unit |
|---|---|---|
| 2 CLP CONTROL | Modbus | |
| 5 THAW MODE | Modbus | |
| 7 IMPULSION MOTOR STATUS | Modbus | |
| 10 INTERIOR TEMPERATURE PROBE STATUS | Modbus | |
| 11 DISCHARGE TEMPERATURE PROBE STATUS | Modbus | |
| 12 OUTDOOR TEMPERATURE PROBE STATUS R | Modbus | |
| 13 STATUS PROBE IMPULSION TEMPERATURE | Modbus | |
| 14 ALARM STATUS OF DIRTY FILTER | Modbus | |
| 6 ENGINE EXTRACTION STATUS | Modbus | |
| 2 BATTERY PRE-HEATING R_W 0 | Modbus | |
| 3 BATTERY POST-HEATING R_W 0 | Modbus | |
| 4 POTENTIAL FREE CONTACT CONTROL SELECTION R_W 0 | Modbus | |
| 6 VERSION SELECTOR R_W 0 | Modbus | |
| 7 MODE ACTIVATION R_W 0 | Modbus | |
| 8 AUTOMATIC CONTROL BYPASS R_W 0 | Modbus | |
| 9 BYPASS MANUAL R_W 0 | Modbus | |
| 12 DIRTY FILTER ALARM RESET (BY TIME) | Modbus | |
| 13 RESTORE FACTORY PARAMETERS W | Modbus | |
| 1 VERSION R | Modbus | |
| 6 SOFTWARE VERSION CENTRAL UNITY | Modbus | <v.1> |
| 7 REMOTE SOFTWARE VERSION | Modbus | <v.1> |
| 8 CONSOLE PROGRAMMING SOFTWARE VERSION | Modbus | <v.1> |
| 9 TYPE OF DOUBLE FLOW | Modbus | <v.1> |
| 10 TIPE OF REGULATION | Modbus | <v.2> |
| 12 FLOW OFFSET | Modbus | <v.1> |
| 13 MINIMUM FLOW | Modbus | <v.1> |
| 14 TIMED HIGH FLOW 1_2H _ BOOST | Modbus | <v.1> |
| 15 HIGH FLOW _ FREE COOLING | Modbus | <v.1> |
| 16 ACTUAL FLOW | Modbus | <v.1> |
| 17 MEASURED TENSION 0-10V | Modbus | <v.1> |
| 19 EXTRACTION ENGINE REVOLUTIONS | Modbus | <v.1> |
| 20 IMPULSE ENGINE REVOLUTIONS | Modbus | <v.1> |
| 21 TEMPERATURE INT | Modbus | ºC |
| 22 TEMPERATURE EXT | Modbus | ºC |
| 23 TEMPERATURE Tex | Modbus | ºC |
| 24 IMPULSION TEMPERATURE | Modbus | ºC |
| 25 BYPASS STATE | Modbus | <v.1> |
| 26 BATTERY STATUS PREHEATING | Modbus | <v.1> |
| 27 POST HEATING BATTERY STATUS | Modbus | <v.1> |
| 37 ALARM TIME OF DIRTY FILTER | Modbus | <v.1> |
| 36 TEMPERATURE Tin BATTERY PREHEATING | Modbus | <v.1> |
| 38 TEMPERATURE Tout PREHEATING BATTERY | Modbus | <v.1> |
| 39 TEMPERATURE Tin POST HEATING BATTERY | Modbus | <v.1> |
| 40 TEMPERATURE Tout POST HEATING BATTERY_ | Modbus | <v.1> |
| 0 INTERFACE MODBUS NODE | Modbus | <v.1> |
| 1 BAUDRATE MODBUS | Modbus | <v.1> |
| 8 SELECTION OF FLOW OFFSET | Modbus | <v.1> |
| 9 LOW FLOW SELECTION | Modbus | <v.1> |
| 10 SELECTION OF TIMED HIGH FLOW 1_2 H _ BOOST | Modbus | <v.1> |
| 11 HIGH FLOW RATE SELECTION _ FREECOOLING | Modbus | <v.1> |
| 15 FLOW SETPOINT | Modbus | <v.1> |
| 16 MINIMUM SETPOINT IN 0‐10V_ | Modbus | <v.1> |
| 17 MAXIMUM SETPOINT IN 0‐10V | Modbus | <v.1> |
| 22 BYPASS AUTO: Text MINIMUM | Modbus | <v.1> |
| 23 BYPASS AUTO: MINIMUM Tint_ | Modbus | <v.1> |
| 24 TIME BYPASS MANUAL | Modbus | <v.1> |
| 25 PRE-HEATING BATTERY Tº ON | Modbus | <v.1> |
| 26 PRE-HEATING BATTERY Tº OFF | Modbus | <v.1> |
| 27 PRE-HEATING BATTERY CONSTANT Tº | Modbus | <v.1> |
| 28 POST-HEATING BATTERY CONSTANT Tº | Modbus | <v.1> |
| 31 TIME SELECTION ALARM OF DIRTY FILTER | Modbus | <v.1> |
| 2 PRE-HEATING BATTERY | Modbus | |
| 3 POST-HEATING BATTERY | Modbus | |
| 4 POTENTIAL FREE CONTACT CONTROL SELECTION | Modbus | |
| 6 VERSION SELECTION | Modbus | |
| 7 MODE ACTIVATION | Modbus | |
| 8 AUTOMATIC BYPASS CONTROL | Modbus | |
| 9 BYPASS MANUAL | Modbus | |
| 12 ALARM RESET OF DIRTY FILTER (BY TIME) | Modbus | |
| 8 FLOW OFFSET SELECTION | Modbus | <v.1> |
| 9 LOW FLOW SELECTION | Modbus | <v.1> |
| 10 SELECTION OF TIMED HIGH FLOW 1_2 H _ BOOST | Modbus | <v.1> |
| 11 HIGH FLOW RATE SELECTION _ FREECOOLING | Modbus | <v.1> |
| 15 FLOW OFFSET | Modbus | <v.1> |
| 16 MINIMUM SETPOINT IN 0‐10V | Modbus | <v.1> |
| 17 MAXIMUM SETPOINT IN 0‐10V | Modbus | <v.1> |