POOL TECHNOLOGIE - ELPO
Content languageEnglish
Description
Poolsquad Pro is a premium saltwater chlorinator system regulated by ORP probe and including pH regulation. This combined system ensures complete desinfection of the pool. The ORP probe measures the water quality in order to control chlorine production. ORP regulation limits the risk of surchloration and protect the pool equipments. A smart pH regulation is also integrated to ensures a balanced water. This template is compatible with all Pool Technologie device having a product reference as ELPOXXXXXX-G4 / G5.
Functions :
- Control electrolysis mode (ORP, %, OFF) - Control pH mode (ON, OFF) - Control Boost state (ON, OFF) - Adjust the different setpoints (pH, ORP, %, time of the boost) - Visualization of the real time values (Salt, Temperature, pH, ORP (mV), %) - Visualization of the active alarms & informations - Consult system informations (ID Code, Serial number, Cell counter, Software version)
There are 2 different types of connector on the devices :
Modbus settings: - Parity: None - Baud rate: 9600 - Device address: 10 - Timing: Auto - Stop bits: 1
Inputs and outputs · 36
| Name | Type | Unit |
|---|---|---|
| pH | Modbus | <v.1> |
| Salt | Modbus | g/l |
| Temperature | Modbus | °C |
| Configuration code | Modbus | <v> |
| alarms1-32 | Modbus | <v> |
| first part S/N | Modbus | <v> |
| second part S/N | Modbus | <v> |
| third part S/N | Modbus | <v> |
| fourth part S/N | Modbus | <v> |
| first part boot version | Modbus | <v> |
| second part boot version | Modbus | <v> |
| first part app version | Modbus | <v> |
| second part app version | Modbus | <v> |
| Production | Modbus | % |
| Redox probe | Modbus | mV |
| Electrolysis mode | Modbus | <v> |
| Cell counter | Modbus | h |
| ORP set point | Modbus | mV |
| pH set point | Modbus | <v> |
| Set point percent | Modbus | % |
| pH mode | Modbus | <v> |
| boost remaining time | Modbus | <v> |
| Boost time | Modbus | <v> |
| Boost | Modbus | <v> |
| Electrolysis mode variable | Modbus | <v> |
| Cover | Modbus | <v> |
| Cover type | Modbus | <v> |
| Electrolysis mode | Modbus | <v> |
| pH mode | Modbus | <v> |
| ORP set point | Modbus | <v> |
| pH set point | Modbus | <v> |
| Set point percent | Modbus | <v> |
| Boost set time | Modbus | <v> |
| Boost | Modbus | <v> |
| Electrolysis mode variable | Modbus | <v> |
| boost remaining time | Modbus | <v> |
Ratings and comments
No ratings or comments yet.
Log in to rate, comment or ask a question. Log in