POOL TECHNOLOGIE - ELPH
Content languageEnglish
Description
Poolsquad Duo is a premium saltwater chlorinator system and including pH regulation. This combined system ensures complete desinfection of the pool. A smart pH regulation is also integrated to ensures a balanced water. This template is compatible with all Pool Technologie device having a product reference as ELPHXXXXXX-G4 / G5.
Functions :
- Control electrolysis mode (%, OFF) - Control pH mode (ON, OFF) - Control Boost state (ON, OFF) - Adjust the different setpoints (pH, %, time of the boost) - Visualization of the real time values (Salt, Temperature, pH, %) - Visualization of the active alarms & informations - Visualization of the system informations (ID Code, Serial number, Cell counter, Software version)
There are 2 different types of connector on the devices :
Modbus settings: - Parity: None - Baud rate: 9600 - Device address: 10 - Timing: Auto - Stop bits: 1
Inputs and outputs · 34
| Name | Type | Unit |
|---|---|---|
| pH | Modbus | <v.1> |
| Salt | Modbus | g/l |
| Temperature | Modbus | °C |
| Configuration code | Modbus | <v> |
| alarms1-32 | Modbus | <v> |
| first part S/N | Modbus | <v> |
| second part S/N | Modbus | <v> |
| third part S/N | Modbus | <v> |
| fourth part S/N | Modbus | <v> |
| first part boot version | Modbus | <v> |
| second part boot version | Modbus | <v> |
| first part app version | Modbus | <v> |
| second part app version | Modbus | <v> |
| Production | Modbus | % |
| Redox probe | Modbus | mV |
| Electrolysis mode | Modbus | <v> |
| Cell counter | Modbus | h |
| pH set point | Modbus | <v> |
| Set point percent | Modbus | % |
| pH mode | Modbus | <v> |
| boost remaining time | Modbus | <v> |
| Boost time | Modbus | <v> |
| Boost | Modbus | <v> |
| Electrolysis mode variable | Modbus | <v> |
| Cover | Modbus | <v> |
| Cover type | Modbus | <v> |
| Electrolysis mode | Modbus | <v> |
| pH mode | Modbus | <v> |
| pH set point | Modbus | <v> |
| Set point percent | Modbus | <v> |
| Boost set time | Modbus | <v> |
| Boost | Modbus | <v> |
| Electrolysis mode variable | Modbus | <v> |
| boost remaining time | Modbus | <v> |
Ratings and comments
No ratings or comments yet.
Log in to rate, comment or ask a question. Log in