POOL TECHNOLOGIE - ELPA
Content languageEnglish
Description
Poolsquad Ampero is a premium saltwater amperometric chlorinator system and including pH regulation. This combined system ensures complete desinfection of the pool. The system measures the free chlorine rate and control the chlorine rate in the pool. A smart pH regulation is also integrated to ensures a balanced water. This template is compatible with all Pool Technologie device having a product reference as ELPAXXXXXX-G4 / G5.
Functions :
- Control electrolysis mode (Cl, %, OFF) - Control pH mode (ON, OFF) - Control Boost state (ON, OFF) - Adjust the different setpoints (pH, Cl, %, time of the boost) - Visualization of the real time values (Salt, Temperature, pH, Cl (ppm), %) - Visualization of the active alarms & informations - Visualization of the system informations (ID Code, Serial number, Cell counter, Software version)
There are 2 different types of connector on the devices :
Modbus settings: - Parity: None - Baud rate: 9600 - Device address: 10 - Timing: Auto - Stop bits: 1
Inputs and outputs · 34
| Name | Type | Unit |
|---|---|---|
| pH | Modbus | <v.1> |
| Salt | Modbus | g/l |
| Temperature | Modbus | °C |
| Configuration code | Modbus | <v> |
| alarms1-32 | Modbus | <v> |
| first part S/N | Modbus | <v> |
| second part S/N | Modbus | <v> |
| third part S/N | Modbus | <v> |
| fourth part S/N | Modbus | <v> |
| first part boot version | Modbus | <v> |
| second part boot version | Modbus | <v> |
| first part app version | Modbus | <v> |
| second part app version | Modbus | <v> |
| Production | Modbus | % |
| CL probe | Modbus | ppm |
| Electrolysis mode | Modbus | <v> |
| Cell counter | Modbus | h |
| CL set point | Modbus | ppm |
| pH set point | Modbus | <v> |
| Set point percent | Modbus | % |
| pH mode | Modbus | <v> |
| boost remaining time | Modbus | <v> |
| Boost time | Modbus | <v> |
| Boost | Modbus | <v> |
| Cover | Modbus | <v> |
| Cover type | Modbus | <v> |
| Electrolysis mode | Modbus | <v> |
| pH mode | Modbus | <v> |
| CL set point | Modbus | <v> |
| pH set point | Modbus | <v> |
| Set point percent | Modbus | <v> |
| Boost set time | Modbus | <v> |
| Boost | Modbus | <v> |
| boost remaining time | Modbus | <v> |
Ratings and comments
No ratings or comments yet.
Log in to rate, comment or ask a question. Log in