Template
Paradigma SystaComfort II
Content languageEnglish
Description
Allows to use the Paradigma SystaComfort II heating controller in Loxone, reading out all temperatures, activating hot water circulation, activating the heating, etc
Paradigma is a German company, so the attached modbus documentation is only available in German unfortunately.
You can use the template to enable or disable heating for one of the zones in your heating system (see screenshot attached). This enables or disables the pump for the given circuit.
Inputs and outputs · 46
| Name | Type | Unit |
|---|---|---|
| Solar day yield | Modbus | <v.1> |
| Testbit | Modbus | <v.1> |
| Temp Outside (TA) | Modbus | °C |
| Temp CV1 Supply (TV) | Modbus | °C |
| Temp CV1 Return (TR) | Modbus | °C |
| Temp Heating Tank San (TWEE) | Modbus | °C |
| Temp Heating Tank Middle (TPO) | Modbus | °C |
| Temp Heating Tank Bottom (TPU) | Modbus | °C |
| Temp Circulation Return (TZR) | Modbus | °C |
| Temp CV2 Supply (TV2) | Modbus | °C |
| Temp CV2 Return (TR2) | Modbus | °C |
| Temp CV1 Room (RI1) | Modbus | °C |
| Temp CV2 Room (RI2) | Modbus | °C |
| Temp Solar Collector (TSA) | Modbus | °C |
| Temp CV Kettle Supply (FATV) | Modbus | °C |
| Temp CV Kettle Return (FATR) | Modbus | °C |
| Temp CV3 Supply (TV3) | Modbus | °C |
| Temp CV3 Return (TR3) | Modbus | °C |
| Temp Solar Supply (TSE) | Modbus | °C |
| Temp Heating Tank Top (TW) | Modbus | °C |
| Temp Solar Return (TSV) | Modbus | °C |
| Solar Flow Rate (S) | Modbus | l/min |
| Temp Solar Outside (TAM) | Modbus | °C |
| Temp San Tank (TSP) | Modbus | °C |
| Temp San Out (TWW) | Modbus | °C |
| Temp San In (TKW) | Modbus | °C |
| San Flow Rate (VKW) | Modbus | l/min |
| San Flow Rate Tank (VSPm) | Modbus | l/min |
| San Heating On | Modbus | |
| San Heating Blocked | Modbus | |
| Temp CV1 Supply Setpoint (TV) | Modbus | °C |
| Temp CV2 Supply Setpoint (TV2) | Modbus | °C |
| Temp CV3 Supply Setpoint | Modbus | °C |
| Status CV2 | Modbus | <v.1> |
| Status CV1 | Modbus | <v.1> |
| Status CV3 | Modbus | <v.1> |
| San Heating On | Modbus | |
| San Circulation On | Modbus | |
| San Circulation Off | Modbus | |
| San Heating Off | Modbus | |
| Temp CV1 Supply Setpoint (TV) | Modbus | <v.1> |
| Temp CV2 Supply Setpoint (TV2) | Modbus | <v.1> |
| Temp CV3 Supply Setpoint (TV3) | Modbus | <v.1> |
| Temp CV1 Supply Setpoint Percentage (TV) | Modbus | % |
| Temp CV2 Supply Setpoint Percentage (TV2) | Modbus | % |
| Temp CV3 Supply Setpoint Percentage (TV3) | Modbus | % |