Orno OR-WE-417 3-pahse power meter
Content languageEnglish
Description
If you have multiple modbus devices on the same bus you have to use orno software to change the modbus address (default is 1) of the device.
Inputs and outputs · 16
| Name | Type | Unit |
|---|---|---|
| S0 output rate | Modbus | imp/kWh |
| L1 Voltage | Modbus | V |
| L1 Current | Modbus | A |
| Total active energy (kWh) | Modbus | kWh |
| L2 Current | Modbus | A |
| L3 Current | Modbus | A |
| L2 Voltage | Modbus | V |
| L3 Voltage | Modbus | V |
| Active Power (kW) | Modbus | kW |
| Reactive Power (VA) | Modbus | VA |
| Power Factor | Modbus | PF |
| Total Energy IN | Modbus | kWh |
| Total Energy OUT | Modbus | kWh |
| Baud Rate | Modbus | <v> |
| A3 | Modbus | A |
| Modbus ID 715 | Modbus | <v> |
FAQ
No questions have been answered yet.
Questions and answers
got weird results from from the orno 517
OpenHello Folks,
I tried your setup for Orno 517 and got weird results. can you help me to get the orzo 517 running? e.G. L1 Voltage 2733242342424234234234,0V L2 Voltage 2733242342424234234234,0V L3 Voltage 0,0V
Peter P.S. I added 517 to the Modbus directly ion the LOXONE Wallbox Tree
5 replies
Hi. Afaik does the Wallbox currently have some issues with some modbus devices. For me the template works flawlessly. But I have it connected via modbus extension.
hmmm - I also would have the ability to take the extension . bit I think that is not the intention of LOXONE
Hello, I seem to have similar issues (Orno 517 and Wallbox Air modbus). Have you found a solution?
Same issue here on the modbus extension
I believe the issue is caused by having "16bit register" option selected by default. In the manual, all the voltage and also current registers have length of 4, i.e. 32 bits, not 16. Since I have unselected "16bit register" option, I see proper voltage value.
Total energy
OpenIn this module, there are 3 outputs for total energy: - Total active energy (kWh), - Total Energy IN, - Total Energy OUT Which of these is the actual meter reading?
The manual of the Orno 517 doesn*t show Total Energy IN and OUT as output on the display. It only has Total active energy. https://files.orno.pl/manuals/OR-WE-513,516,517_manual_EN.pdf
1 reply
"Total active energy" is in kWh "Total Energy IN" and "Total Energy OUT" is kW