Orisec
Content languageEnglish
Description
If you are required to have a graded alarm system that integrates well with Loxone, than Orisec is your solution.
Once the connection is established you would be able to read all inputs and zones - Motion sensors, contacts etc - both wired and wireless.
NOTE: 1.For the connection to work you need to get the original communication cable ( Com port to RS232) from Orisec. 2.The communication protocol on the Orisec panel needs to be set to CID Serial
You can then get an RS232 Female adapter and use a bit of cat cable to connect RX TX and GND on the RS232 extension:
Once everything is connected, you can test communication with Get Version Output - just put it on a pulse generator and test if you get a response.
When communication is established, you can then request the zones information again with a pulse generator on the GetZone output.(Not required on the bigger panels CP100 and up, due to new hardware)
Note that you need to change the password for the request command such as GETZone - replace 1234 with your own password in the Command field of the Analogue Output
If you have more than 20 zones, then you can just keep on adding device states with a continuation of the command recognition pattern.
Inputs and outputs · 26
| Name | Type | Command | Unit |
|---|---|---|---|
| State 1 | Comm | GETZ:\1 | <v> |
| State 2 | Comm | GETZ:\s1\1 | <v> |
| State 3 | Comm | GETZ:\s2\1 | <v> |
| State 4 | Comm | GETZ:\s3\1 | <v> |
| State 5 | Comm | GETZ:\s4\1 | <v> |
| State 6 | Comm | GETZ:\s5\1 | <v> |
| State 7 | Comm | GETZ:\s6\1 | <v> |
| State 8 | Comm | GETZ:\s7\1 | <v> |
| State 9 | Comm | GETZ:\s8\1 | <v> |
| State 10 | Comm | GETZ:\s9\1 | <v> |
| State 11 | Comm | GETZ:\s10\1 | <v> |
| State 12 | Comm | GETZ:\s11\1 | <v> |
| State 13 | Comm | GETZ:\s12\1 | <v> |
| State 14 | Comm | GETZ:\s13\1 | <v> |
| State 15 | Comm | GETZ:\s14\1 | <v> |
| State 16 | Comm | GETZ:\s15\1 | <v> |
| State 17 | Comm | GETZ:\s16\1 | <v> |
| State 18 | Comm | GETZ:\s17\1 | <v> |
| State 19 | Comm | GETZ:\s18\1 | <v> |
| State 20 | Comm | GETZ:\s19\1 | <v> |
| GETVER | Comm | GETVER | |
| GET Zone | Comm | 1234GETZ | |
| ARM | Comm | 1234ARM | |
| DISARM | Comm | 1234DISARM | |
| GET Partition Status | Comm | 1234GETP | |
| GET Zone 2 | Comm | 1234GETZ:2 |