OpenEMS

by Andreas ByfutNo rating yet875 downloads

Content languageEnglish

Description

This template is written to facilitate reading all avaliable data from OpenEMS based devices such as the Fenecon Pro Hybrid 10 via Modbus TCP.

The implementation is based upon the official API documentation.

For the energy manager, use the virtual inputs:

- sum_GridActivePower for Gpwr - sum_ProductionActivePower for Ppwr - sum_EssDischargePower for Spwr - sum_EssSoc for Soc

Use other virtual inputs for other specific needs.

Inputs and outputs · 39

NameTypeUnit
sum_StateModbus<v>
sum_EssSocModbus%
sum_EssActivePowerModbuskW
sum_GridActivePowerModbuskW
sum_GridMinActivePowerModbuskW
sum_GridMaxActivePowerModbuskW
sum_GridActivePowerL1ModbuskW
sum_GridActivePowerL2ModbuskW
sum_GridActivePowerL3ModbuskW
sum_ProductionActivePowerModbuskW
sum_ProductionMaxActivePowerModbuskW
sum_ProductionAcActivePowerModbuskW
sum_ProductionMaxAcActivePowerModbuskW
sum_ProductionDcActualPowerModbuskW
sum_ProductionMaxDcActualPowerModbuskW
sum_ConsumptionActivePowerModbuskW
sum_ConsumptionMaxActivePowerModbuskW
sum_EssActivePowerL1ModbuskW
sum_EssActivePowerL2ModbuskW
sum_EssActivePowerL3ModbuskW
sum_ProductionAcActivePowerL1ModbuskW
sum_ProductionAcActivePowerL2ModbuskW
sum_ProductionAcActivePowerL3ModbuskW
sum_ConsumptionActivePowerL1ModbuskW
sum_ConsumptionActivePowerL2ModbuskW
sum_ConsumptionActivePowerL3ModbuskW
sum_EssActiveChargeEnergyModbuskWh
sum_EssActiveDischargeEnergyModbuskWh
sum_GridBuyActiveEnergyModbuskWh
sum_GridSellActiveEnergyModbuskWh
sum_ProductionActiveEnergyModbuskWh
sum_ProductionAcActiveEnergyModbuskWh
sum_ProductionDcActiveEnergyModbuskWh
sum_ConsumptionActiveEnergyModbuskWh
sum_EssDcChargeEnergyModbuskWh
sum_EssDcDischargeEnergyModbuskWh
sum_GridModeModbus<v>
sum_EssReactivePowerModbuskW
sum_EssDischargePowerModbuskW

FAQ

No questions have been answered yet.

Ratings and comments

No ratings or comments yet.

Questions and answers

  1. EssActivePower wrong Values

    Open

    Hi,

    the Modbus Value on Register 303 brings a wrong Value. It is not the actual Battery Power.

    Pls help.

    2 replies

    1. You Need Register 415 for the Battery

    2. Hey, as basically already proposed, use instead the virtual input `sum_EssDischargePower`from the plugin which reads the register 415.

  2. Modbus Register

    Open

    In deinem Artikel schreibst du das das Register EssActiveDischargeEnergy die aktuelle Batterie Entladeenergie anzeigt leider ist das in Loxone die gesamte Entladeenergie der Lebenszeit des Speichers. Ich finde leider nirgends die aktuelle Entladeleistung weißt du das register bzw. die Adresse des Registers?

    1 reply

    1. Ich nutze dafür aus dem Plugin den virtuellen Eingang `sum_EssDischargePower`der das Register 415 abfragt.

      Für eine Beschreibung der Register, gehe auf deine openEMS Instanz unter Einstellungen -> Anlagenprofil -> Konfiguration -> Modbus/TCP lesend und klicke auf `Download Protocoll`.

  3. netzdienliche Beladung

    Open

    Könnte man bitte die netzdienliche Beladung (Manuell / Automatisch inkl. der 3 Risikobereitschafts Einstellungen / Aus) als schreibzugriff von Loxone an Fenecon integrieren?

    No replies