OBO Ion Wallbox
Content languageEnglish
Description
This template enables to control the OBO Ion Wallbox using Loxone Modbus Extension.
It supports:
- Enable/disable charging - Set the charge current - Monitor active (CP) state - Monitor EVSE advertised current - Set the behaviour after power loss (continue or disable charge) - Set communication time-out time - Set fallback current if communication fails - Monitor the Error code (Failed diode check, DC residual current fault, RCM self test failed)
The template comes with the default values of the Wallbox:
- address: hexa '0x65' or decimal '101' - baudrate: 19200 bps - parity: even.
For more information:
1. see the uploaded manuals 2. take a look at: OBO Ion Wallbox für Wallboxen | OBO 3. contact us.
Inputs and outputs · 13
| Name | Type | Unit |
|---|---|---|
| EVSE advertised current | Modbus | A |
| Active state | Modbus | <v> |
| Charge disable behaviour on power loss | Modbus | <v> |
| Active charging current | Modbus | A |
| Charge disable | Modbus | <v> |
| Fallback current | Modbus | A |
| Comms time-out | Modbus | ms |
| Error code | Modbus | <v> |
| Fallback current | Modbus | A |
| Charge disable | Modbus | <v> |
| Active charging current | Modbus | A |
| Charge disable behaviour on power loss | Modbus | <v> |
| Comms time-out | Modbus | ms |