Template

my-PV AC ELWA 2

by my-PV GmbHBrand: my-PVNo rating yet838 downloads

Content languageEnglish

Description

Use PV Surplus Power to heat up your Hotwater Boiler.

For the AC ELWA 2 to be controlled by Loxone via Modbus TCP, Modbus TCP must be set as the "control type" in the control settings of the AC ELWA E, and the "control timeout" must be set to 60 seconds. This settings can be made via the Display, more Details in the operation manuell.

https://www.my-pv.com/en/manuals/ac-elwa-2

Inputs and outputs · 11

NameTypeUnit
Read Target TemperaturModbus°C
Read Temperatur T1Modbus°C
Read PowerModbusW
Read Temperatur T2Modbus°C
Read Device StateModbus<v>
Read Operation ModeModbus<v>
Set PowerModbusW
Set Target TemperatureModbus°C
Set Power TimeoutModbussec
Set Device StateModbus<v>
Set Operation ModeModbus<v>

FAQ

No questions have been answered yet.

Ratings and comments

No ratings or comments yet.

Questions and answers

  1. Set Power

    Open

    Ich habe ein Problem mit dem - Set Power. Ich bekomme immer diese Fehlermeldung. Was kann das sein?

    Illegal IO Address (Exception-Code 02)

    No replies