Modbus P1 Gateway
Content languageEnglish
Description
With the Negotica Modbus P1 Gateway you can read data from Smart Meters commonly used in Belgium, The Netherlands and Luxembourg via Modbus TCP or RTU.
Note: For Modbus TCP you need to check property "Order of Registers" on every sensor object.
The Modbus P1 Gateway publishes all possible data objects for all smart meter versions. If the Smart Meter does not support a data object, the value will be "nan". Delete all unused objects to improve performance. Values will be updated every 1 or 10 seconds, depending on the Smart Meter version.
The main template contains all objects. Below you can download a template with only the most commonly used objects for Belgium or The Netherlands.
For more information and ordering the Modbus P1 Gateway check out: https://www.negotica.net/gtwmp1
Inputs and outputs · 61
| Name | Type | Unit |
|---|---|---|
| 000. Version information for P1 output | Modbus | <v> |
| 002. Meter Reading electricity delivered to client (Tariff 1) in 0,001 kWh | Modbus | kWh |
| 004. Meter Reading electricity delivered to client (Tariff 2) in 0,001 kWh | Modbus | kWh |
| 006. Meter Reading electricity delivered by client (Tariff 1) in 0,001 kWh | Modbus | kWh |
| 008. Meter Reading electricity delivered by client (Tariff 2) in 0,001 kWh | Modbus | kWh |
| 010. Tariff indicator electricity. | Modbus | <v> |
| 012. Actual electricity power delivered (+P) in 1 Watt resolution | Modbus | kW |
| 014. Actual electricity power received (-P) in 1 Watt resolution | Modbus | kW |
| 016. Number of power failures in any phase | Modbus | <v> |
| 018. Number of long power failures in any phase | Modbus | <v> |
| 020. Number of voltage sags in phase L1 | Modbus | <v> |
| 022. Number of voltage sags in phase L2 | Modbus | <v> |
| 024. Number of voltage sags in phase L3 | Modbus | <v> |
| 026. Number of voltage swells in phase L1 | Modbus | <v> |
| 028. Number of voltage swells in phase L2 | Modbus | <v> |
| 030. Number of voltage swells in phase L3 | Modbus | <v> |
| 032. Instantaneous voltage L1 in V resolution | Modbus | V |
| 034. Instantaneous voltage L2 in V resolution | Modbus | V |
| 036. Instantaneous voltage L3 in V resolution | Modbus | V |
| 038. Instantaneous current L1 in A resolution. | Modbus | A |
| 040. Instantaneous current L2 in A resolution. | Modbus | A |
| 042. Instantaneous current L3 in A resolution. | Modbus | A |
| 044. Instantaneous active power L1 (+P) in W resolution | Modbus | kW |
| 046. Instantaneous active power L2 (+P) in W resolution | Modbus | kW |
| 048. Instantaneous active power L3 (+P) in W resolution | Modbus | kW |
| 050. Instantaneous active power L1 (-P) in W resolution | Modbus | kW |
| 052. Instantaneous active power L2 (-P) in W resolution | Modbus | kW |
| 054. Instantaneous active power L3 (-P) in W resolution | Modbus | kW |
| 056. The actual threshold Electricity in A | Modbus | A |
| 058. Actual switch position Electricity (in/out) | Modbus | <v> |
| 060. Actual switch position Electricity (in/out) | Modbus | <v> |
| 062. Text message codes: numeric 8 digits | Modbus | <v> |
| 064. Device-Type slave meter 1 (probably gas) | Modbus | <v> |
| 066. Last meter reading slave meter 1 (probably gas) | Modbus | m³ |
| 068. Last meter reading slave meter 1 (probably gas) | Modbus | m³ |
| 070. Valve position (on/off/released) slave meter 1 (probably gas) | Modbus | <v> |
| 072. Device-Type slave meter 2 | Modbus | <v> |
| 074. Last meter reading slave meter 2 | Modbus | m³ |
| 076. Last meter reading slave meter 2 | Modbus | m³ |
| 078. Valve position (on/off/released) slave meter 2 | Modbus | <v> |
| 080. Device-Type slave meter 3 | Modbus | <v> |
| 082. Last meter reading slave meter 3 | Modbus | m³ |
| 084. Last meter reading slave meter 3 | Modbus | m³ |
| 086. Valve position (on/off/released) slave meter 3 | Modbus | <v> |
| 088. Device-Type slave meter 4 | Modbus | <v> |
| 090. Last meter reading slave meter 4 | Modbus | m³ |
| 092. Last meter reading slave meter 4 | Modbus | m³ |
| 094. Valve position (on/off/released) slave meter 4 | Modbus | <v> |
| 096. Last Meter reading Gas in 0,001 m3 | Modbus | m³ |
| 098. Last Meter reading Gas in 0,001 m3 temperature compensated | Modbus | m³ |
| 100. Valve position Gas (on/off/released) | Modbus | <v> |
| 102. Last meter reading Heat in 0,01 GJ | Modbus | GJ |
| 104. Last meter reading Cold in 0,01 GJ | Modbus | GJ |
| 106. Last meter reading Water in 0,001 m3 | Modbus | m³ |
| 108. Last value of not temperature corrected gas volume in m3 slave meter 1 (BE) | Modbus | m³ |
| 110. Last value of not temperature corrected gas volume in m3 slave meter 2 (BE) | Modbus | m³ |
| 112. Last value of not temperature corrected gas volume in m3 slave meter 3 (BE) | Modbus | m³ |
| 114. Last value of not temperature corrected gas volume in m3 slave meter 4 (BE) | Modbus | m³ |
| 116. Version information (BE) | Modbus | <v> |
| 118. Breaker state (BE) | Modbus | <v> |
| 120. Fuse supervision threshold (L1) (BE) | Modbus | A |