Template

Modbus P1 Gateway

by Negotica Development ProjectsBrand: NegoticaNo rating yet948 downloads

Content languageEnglish

Description

With the Negotica Modbus P1 Gateway you can read data from Smart Meters commonly used in Belgium, The Netherlands and Luxembourg via Modbus TCP or RTU.

Note: For Modbus TCP you need to check property "Order of Registers" on every sensor object.

The Modbus P1 Gateway publishes all possible data objects for all smart meter versions. If the Smart Meter does not support a data object, the value will be "nan". Delete all unused objects to improve performance. Values will be updated every 1 or 10 seconds, depending on the Smart Meter version.

The main template contains all objects. Below you can download a template with only the most commonly used objects for Belgium or The Netherlands.

For more information and ordering the Modbus P1 Gateway check out: https://www.negotica.net/gtwmp1

Inputs and outputs · 61

NameTypeUnit
000. Version information for P1 outputModbus<v>
002. Meter Reading electricity delivered to client (Tariff 1) in 0,001 kWhModbuskWh
004. Meter Reading electricity delivered to client (Tariff 2) in 0,001 kWhModbuskWh
006. Meter Reading electricity delivered by client (Tariff 1) in 0,001 kWhModbuskWh
008. Meter Reading electricity delivered by client (Tariff 2) in 0,001 kWhModbuskWh
010. Tariff indicator electricity.Modbus<v>
012. Actual electricity power delivered (+P) in 1 Watt resolutionModbuskW
014. Actual electricity power received (-P) in 1 Watt resolutionModbuskW
016. Number of power failures in any phaseModbus<v>
018. Number of long power failures in any phaseModbus<v>
020. Number of voltage sags in phase L1Modbus<v>
022. Number of voltage sags in phase L2Modbus<v>
024. Number of voltage sags in phase L3Modbus<v>
026. Number of voltage swells in phase L1Modbus<v>
028. Number of voltage swells in phase L2Modbus<v>
030. Number of voltage swells in phase L3Modbus<v>
032. Instantaneous voltage L1 in V resolutionModbusV
034. Instantaneous voltage L2 in V resolutionModbusV
036. Instantaneous voltage L3 in V resolutionModbusV
038. Instantaneous current L1 in A resolution.ModbusA
040. Instantaneous current L2 in A resolution.ModbusA
042. Instantaneous current L3 in A resolution.ModbusA
044. Instantaneous active power L1 (+P) in W resolutionModbuskW
046. Instantaneous active power L2 (+P) in W resolutionModbuskW
048. Instantaneous active power L3 (+P) in W resolutionModbuskW
050. Instantaneous active power L1 (-P) in W resolutionModbuskW
052. Instantaneous active power L2 (-P) in W resolutionModbuskW
054. Instantaneous active power L3 (-P) in W resolutionModbuskW
056. The actual threshold Electricity in AModbusA
058. Actual switch position Electricity (in/out)Modbus<v>
060. Actual switch position Electricity (in/out)Modbus<v>
062. Text message codes: numeric 8 digitsModbus<v>
064. Device-Type slave meter 1 (probably gas)Modbus<v>
066. Last meter reading slave meter 1 (probably gas)Modbusm³
068. Last meter reading slave meter 1 (probably gas)Modbusm³
070. Valve position (on/off/released) slave meter 1 (probably gas)Modbus<v>
072. Device-Type slave meter 2Modbus<v>
074. Last meter reading slave meter 2Modbusm³
076. Last meter reading slave meter 2Modbusm³
078. Valve position (on/off/released) slave meter 2Modbus<v>
080. Device-Type slave meter 3Modbus<v>
082. Last meter reading slave meter 3Modbusm³
084. Last meter reading slave meter 3Modbusm³
086. Valve position (on/off/released) slave meter 3Modbus<v>
088. Device-Type slave meter 4Modbus<v>
090. Last meter reading slave meter 4Modbusm³
092. Last meter reading slave meter 4Modbusm³
094. Valve position (on/off/released) slave meter 4Modbus<v>
096. Last Meter reading Gas in 0,001 m3Modbusm³
098. Last Meter reading Gas in 0,001 m3 temperature compensatedModbusm³
100. Valve position Gas (on/off/released)Modbus<v>
102. Last meter reading Heat in 0,01 GJModbusGJ
104. Last meter reading Cold in 0,01 GJModbusGJ
106. Last meter reading Water in 0,001 m3Modbusm³
108. Last value of not temperature corrected gas volume in m3 slave meter 1 (BE)Modbusm³
110. Last value of not temperature corrected gas volume in m3 slave meter 2 (BE)Modbusm³
112. Last value of not temperature corrected gas volume in m3 slave meter 3 (BE)Modbusm³
114. Last value of not temperature corrected gas volume in m3 slave meter 4 (BE)Modbusm³
116. Version information (BE)Modbus<v>
118. Breaker state (BE)Modbus<v>
120. Fuse supervision threshold (L1) (BE)ModbusA