MENNEKES AMTRON® Xtra & Premium
Content languageEnglish
Description
The sample project shows a possible implementation of your AMTRON® via Modbus TCP. For this purpose the Loxone function block "wallbox" is used.
In the meanwhile there are two wallbox function blocks, for each of them there is a sample project:
- wallbox Gen1: MENNEKES_AMTRON_Xtra_Premium.Loxone - wallbox Gen2: MENNEKES_AMTRON_Xtra_Premium_v2.Loxone (UPDATE!!!)
Just import the template in your project and replace "PV Power" by your own value.
Here you can find further information about the supported AMTRON® Xtra and Premium charging stations:
- AMTRON® Xtra 11 - AMTRON® Xtra 11 C2 - AMTRON® Xtra 22 C2 - AMTRON® Premium 3,7 - AMTRON® Premium 3,7 C2 - AMTRON® Premium 11 - AMTRON® Premium 11 C2 - AMTRON® Premium 22 C2
It is necessary to update your AMTRON® to a software version 1.13 (or higher) to enable the function Modbus TCP.
The update itself and a description how to install it can be found here:
- Software Update
Functions:
- remote start (and pause) via the Loxone web interface in addition to using the Charge App - Loxone web interface can also be easily controlled via the mobile network to control your AMTRON® - 3 modes for charge limitation within the Loxone web interface - intelligent: can be used for solar optimized charging (implemented in the project as a manual current limitation) - manual: charging power can be adjusted by a slide control - maximum: no limitation - live values - total charging power - charged energy and duration of the charging session - internal temperatures - connected cable type - daily statistics of your charging history - online status of the wallbox - check status of the parameters of your AMTRON® as set in the service interface - operation mode (remote, time-managed, external switch) - autostart charging enabled - RFID authorization enabled (only AMTRON® Premium) - EV wake-up enabled - energy manager installed - reset statistics of your charging history - reboot your AMTRON®
Remarks:
- Your Charge App for Android or iOS can still be used to control and check your AMTRON®. - The function of autostart charging and RFID authorization (only for AMTRON® Premium) can still be used without any changes in the service interface or any settings within the Loxone project.
It is highly recommended to set up a static IP address for your AMTRON®. Within the Loxone project this IP address has to be assigned to the Modbus server to find your AMTRON in your IP network.
Feel free to customize the project to your needs and don't hesitate to give us feedback. Your team from MENNEKES.
Inputs and outputs · 19
| Name | Type | Unit |
|---|---|---|
| Temperature (extern) | Modbus | °C |
| Temperature (intern) | Modbus | °C |
| CP State | Modbus | <v> |
| PP State | Modbus | <v> |
| Error Code | Modbus | Fehlercode |
| AMTRON State | Modbus | <v> |
| Charged Energy | Modbus | kWh |
| Actual Power Consumption | Modbus | kW |
| Rated Current | Modbus | A |
| Installation Current | Modbus | A |
| Number of Phases | Modbus | <v> |
| Autostart Charging | Modbus | <v> |
| RFID Authorization | Modbus | <v> |
| Energy Manager Installed | Modbus | <v> |
| EV Wake-Up | Modbus | <v> |
| Operation Mode | Modbus | <v> |
| Change Charge State | Modbus | <v> |
| Current Limitation | Modbus | A |
| Reboot AMTRON | Modbus | <v> |