MENNEKES AMTRON® Compact 2.0s & Start 2.0s

by MENNEKES Elektrotechnik GmbH & Co. KGNo rating yet547 downloads

Content languageEnglish

Description

The charging stations AMTRON® Compact 2.0s & Start 2.0s use Modbus RTU to interact with the Loxone system (Loxone Modbus RTU extension needed).

Here you can find further information about the supported AMTRON® charging stations:

- AMTRON® Compact 2.0s - AMTRON® Start 2.0s

Please be sure to have the latest software update installed on your wallbox:

- use the MENNEKES configuration cable together with the latest version of the MENNEKES configuration tool (v2.2) - supported version of the wallbox software for the charging station: at least v2.0 (03/2024), current version v2.2 (07/2025)

To use the charging station as a solar controlled modbus satellite, set the DIPs 4,5 and 7 of bank S1 to "ON" and restart the wallbox.

For dynamic phase switch (automatic switch between 1- and 3-phase charging) it is necessary to have the option "dynamic phase switch" activated via the MENNEKES configuration tool (https://www.mennekes.de/emobility/produkt-details/mennekes-konfigurationskabel-18625/).

MENNEKES Modbus RTU uses the following communication parameters per default:

- Baudrate 57600 bit/s - 8 Data bits - 2 Stop bits - modbus address of the wallbox: 50 - With wallbox software v2.0 it is also possible to adjust the Modbus settings regarding your needs (baudrate, data format, modbus address). - >>> For more details regarding the modbus specification: check the attached description.

The minimal registers needed to control your AMTRON® Compact 2.0s or Start 2.0s are:

- Heartbeat: 21930 (cyclic, at least every 10s) - Charging Current: 6...16/32A - Charging Release: 0=prevent charging, 1=allow charging

You can also use the attached template (UPDATE 2023-06-19, bugfix in status block "phase usage") including the usage of the phase switching option for the AMTRON® with 11kW. Just replace the "PV Power" with your own live value.


Feel free to customize the project to your needs and don't hesitate to give us feedback. Thanks to the users who already helped us improving the template. Your team from MENNEKES.

Inputs and outputs · 53

NameTypeUnit
53_Voltage L1ModbusV
54_Voltage L2ModbusV
55_Voltage L3ModbusV
50_Current L1ModbusA
52_Current L3ModbusA
51_Current L2ModbusA
56_Power L1ModbusW
57_Power L2ModbusW
58_Power L3ModbusW
59_Power OverallModbusW
10_EVSE StateModbus<v>
71_Charged Energy SessionModbuskWh
72_Duration SessionModbuss
01_Modbus VersionModbus<v>
04_HW VersionModbus<v>
05_Product IDModbus<v>
11_Authorization StatusModbus<v>
12_DowngradeModbus<v>
13_Phase RotationModbus<v>
30_Downgrade CurrentModbusA
31_Charging Current Energy ManagerModbusA
32_Max Current House (DIP)ModbusA
33_Max Current EVSEModbusA
34_Phase Options SolarModbus<v>
70_Max Current SessionModbusA
82_Cable LockModbus<v>
83_Solar Charging ModeModbus<v>
84_Requested PhasesModbus<v>
85_Charging ReleaseModbus<v>
86_Lock EVSEModbus<v>
90_Active Error CodeModbus<v>
18_CP StateModbus<v>
36_Phase Mode HWModbus<v>
37_Cable LockModbus<v>
38_Master Lost Fallback CurrentModbus<v>
39_Grid InbalanceModbus<v>
40_Grid Inbalance ThresholdModbusA
41_Grid Phases ConnectedModbus<v>
42_AuthorizationModbus<v>
44_Phase Switching PauseModbuss
43_Sunshine+ CurrentModbusA
60_TemperatureModbus°C
73_Detected EV PhasesModbusEV phases
91_Master Lost Fallback StateModbus<v>
92_Switched PhasesModbus<v>
100_Charged Energy TotalModbuskWh
101_Charging Sessions TotalModbus<v>
80_Heartbeat 0x55AAModbus<v>
85_Set Charging ReleaseModbus<v>
31_Set Charging Current Energy ManagerModbus<v.1>
83_Set Solar Charging ModeModbus<v>
84_Set Requested PhasesModbus<v>
86_Set Lock EVSEModbus<v>