Kostal Inverter
Description
Read values of your Kostal inverter via RS485.
Inputs and outputs · 17
| Name | Type | Command | Unit |
|---|---|---|---|
| Total energy | Comm | 1:totalenergy:\v | Wh |
| Day energy | Comm | 1:dayenergy:\v | Wh |
| State | Comm | 1:state:\v | <v> |
| Error | Comm | 1:error\v | <v> |
| Errorcode | Comm | 1:ecode:\v | <v> |
| Generator voltage 1 | Comm | 1:US1:\v | V |
| Generator voltage 2 | Comm | 1:US2:\v | V |
| Generator voltage 3 | Comm | 1:US3:\v | V |
| Generator current 1 | Comm | 1:IS1:\v | A |
| Generator current 2 | Comm | 1:IS2:\v | A |
| Generator current 3 | Comm | 1:IS3:\v | A |
| Output voltage 1 | Comm | 1:UP1:\v | V |
| Output voltage 2 | Comm | 1:UP2:\v | V |
| Output voltage 3 | Comm | 1:UP3:\v | V |
| Output power 1 | Comm | 1:PP1:\v | W |
| Output power 2 | Comm | 1:PP2:\v | W |
| Output power 3 | Comm | 1:PP3:\v | W |
FAQ
No questions have been answered yet.
Questions and answers
Einbindung Kostal Wechselrichter über RS485 Extension
OpenHallo, ich habe meinen Kostal Wechselrichter (Plenticore 10 Plus) über die RS485 Schnittstelle und eure RS485 Extension eingebunden. Leider liefert mir diese aber keine Wert und ich stehe an mit meinen Recherchen. Bitte um Unterstützung, danke und lg Markus
1 reply
Hello Markus,
I have taken a look at the online documentation of the Plenticore 10 Plus and after looking at this documentation. I see that the battery is using a hardware RS485 communication interface with modbus protocol. This means that you will not be able to use this template or RS485 extension but you will need a Modbus extension or modbus Air to get this device into loxone.
Log in to rate, comment or ask a question. Log in