Komfovent DOMEKT C8
Content languageEnglish
Description
The product range includes vertical, horizontal, and flat configurations equipped with either rotary or counterflow plate heat exchangers. All units are built around advanced control systems that optimize ventilation, heating, cooling, and air quality while keeping operational costs low.
The integrated C8 control platform provides intuitive operation for everyday users and extensive configuration options for HVAC professionals. The core philosophy behind the design of C8 – the ventilation unit would operate properly without constant adjustments from the user. Ventilation modes are optimized for daily use and can switch automatically according to air quality or user-defined schedules.
Advanced features support both comfort and efficiency: · Fan intensity control separately for supply and extract flows. · Temperature management with supply, extract, and room-based control strategies · Automatic air quality control via CO₂ and humidity sensors · Seasonal energy-saving functions such as cool recovery, free cooling, and temperature saving · Support for external devices, including water coils and DX units · Weekly and holiday schedules, timed modes, and on-demand ventilation · Comprehensive safety and protection mechanisms (frost protection, overheat protection, fire alarms, and critical temperature shutdown) · Smart diagnostics, filter status monitoring, and detailed runtime counters Connectivity options include a web interface and cloud-based smartphone control enabling remote operation, monitoring, firmware updates, and service diagnostics. Integrated Modbus TCP/IP protocol is compatible with Loxone devices as well. Together, these features ensure that DOMEKT units deliver reliable, efficient, and user-friendly ventilation suited for modern residential environments.
For more information on DOMEKT residential units, please visit Komfovent webpage
Inputs and outputs · 38
| Name | Type | Unit |
|---|---|---|
| Return water temperature | Modbus | °C |
| Current mode | Modbus | <v> |
| Active alarms count | Modbus | <v> |
| Supply temperature | Modbus | °C |
| ON/OFF status | Modbus | <v> |
| ECO mode | Modbus | <v> |
| AUTO mode | Modbus | <v> |
| Current supply fan intensivity | Modbus | % |
| Current extract fan intensivity | Modbus | % |
| Heat exchanger | Modbus | % |
| Panel 2 humidity | Modbus | % |
| Extract temperature | Modbus | °C |
| Filters Impurity | Modbus | % |
| Water cooler | Modbus | % |
| Electric heater | Modbus | % |
| Water heater | Modbus | % |
| DX unit | Modbus | % |
| Outdoor temperature | Modbus | °C |
| Panel 2 temperature | Modbus | °C |
| Panel 1 temperature | Modbus | °C |
| Panel 1 humidity | Modbus | % |
| Connected panels | Modbus | <v> |
| Sensor (B8) | Modbus | <v> |
| Active alarm 1 code | Modbus | <v> |
| Active alarm 2 code | Modbus | <v> |
| Active alarm 3 code | Modbus | <v> |
| Set Current mode | Modbus | <v> |
| Set ON/OFF status | Modbus | <v> |
| AUTO mode | Modbus | <v> |
| ECO mode | Modbus | <v> |
| Boost (Temperature setpoint) | Modbus | °C |
| Scheduler operation mode | Modbus | <v> |
| Temperature control mode | Modbus | <v> |
| Intensive (Temperature setpoint) | Modbus | °C |
| Away (Temperature setpoint) | Modbus | °C |
| Normal (Temperature setpoint) | Modbus | °C |
| Reset active alarms | Modbus | <v> |
| Clean filters calibration | Modbus | <v> |