Komfovent C5: VERSO, KLASIK
Content languageEnglish
Description
The KOMFOVENT C5 control system is designed for VERSO, RHP and KLASIK air handling units, ensuring reliable and efficient operation across a wide range of building applications. It provides stable performance, flexible control and seamless integration into building systems, making it suitable for both standalone installations and more complex HVAC networks.
The C5 platform offers a balanced combination of functionality and ease of use. It allows users to manage multiple units, adjust operating parameters and monitor system performance through a clear and accessible interface. Designed with everyday operation and professional use in mind, the C5 control system ensures that ventilation systems operate consistently and efficiently.
Advanced features support both comfort and efficiency:
- Flexible airflow control, including CAV, VAV and DCV modes - Temperature management with supply, extract and room-based control strategies - Automatic air quality control via CO₂ and humidity sensors - Seasonal energy-saving functions such as cool recovery, free cooling, recirculation and temperature saving - Support for external devices, including water coils, multi-step electric heaters, DX units and humidifiers - Integrated heat pump solutions – manage all indoor climate processes from a single user interface - Weekly and holiday schedules, timed modes and on-demand ventilation - Comprehensive safety and protection mechanisms: frost protection, overheating protection, fire alarms and critical temperature shutdown - Smart diagnostics with constant monitoring of all internal electronics, fans, and frequency inverters, with more than 300 available alarms and informational messages for easy troubleshooting
For more information, please visit Komfovent webpage
Inputs and outputs · 46
| Name | Type | Unit |
|---|---|---|
| Return water temperature | Modbus | °C |
| Current mode | Modbus | <v> |
| Active alarms count | Modbus | <v> |
| Exhaust temperature | Modbus | °C |
| Supply temperature | Modbus | °C |
| Current supply flow | Modbus | <v> |
| Current extract flow | Modbus | <v> |
| ON/OFF status | Modbus | <v> |
| Supply fan level | Modbus | % |
| Exhaust fan level | Modbus | % |
| Energy saving | Modbus | % |
| Heat exchanger efficiency | Modbus | % |
| Heat exchanger recovery | Modbus | W |
| Heat exchanger | Modbus | % |
| Extract temperature | Modbus | °C |
| Outdoor air filter impurity level | Modbus | % |
| Water cooler level | Modbus | % |
| Electric heater level | Modbus | % |
| Water heater level | Modbus | % |
| DX unit level | Modbus | % |
| Outdoor temperature | Modbus | °C |
| Current supply air humidity | Modbus | % |
| Current air quality level | Modbus | <v> |
| Active alarm 1 code | Modbus | <v> |
| Active alarm 2 code | Modbus | <v> |
| Active alarm 3 code | Modbus | <v> |
| HP/CF Defrost | Modbus | <v> |
| Heat pump level | Modbus | % |
| Exhaust air filter impurity level | Modbus | % |
| Set Current mode | Modbus | <v> |
| Set ON/OFF status | Modbus | <v> |
| Comfort2 (Supply flow setpoint) | Modbus | <v> |
| Comfort2 (Temperature setpoint) | Modbus | °C |
| Temperature control mode | Modbus | <v> |
| Comfort1 (Supply flow setpoint) | Modbus | <v> |
| Economy2 (Supply flow setpoint) | Modbus | <v> |
| Economy1 (Supply flow setpoint) | Modbus | <v> |
| Comfort1 (Extract flow setpoint) | Modbus | <v> |
| Economy2 (Extract flow setpoint) | Modbus | <v> |
| Economy1 (Extract flow setpoint) | Modbus | <v> |
| Comfort2 (Extract flow setpoint) | Modbus | <v> |
| Economy1 (Temperature setpoint) | Modbus | °C |
| Comfort1 (Temperature setpoint) | Modbus | °C |
| Economy2 (Temperature setpoint) | Modbus | °C |
| Clean filters calibration | Modbus | <v> |
| Reset active alarms | Modbus | <v> |