Template
KEBA Heat Distribution
Description
Control your KEBA Heat distribution unit via Modbus.
Inputs and outputs · 55
| Name | Type | Unit |
|---|---|---|
| >Control Status | Modbus | ° |
| Target temperature heating circuit 1 | Modbus | ° |
| Room temperature heating circuit 1 | Modbus | ° |
| Room humidity heating circuit 1 | Modbus | % |
| Operating mode heating circuit 1 | Modbus | <v.0> |
| Heating requirement heating circuit 1 | Modbus | <v.0> |
| Target temperature heating circuit 2 | Modbus | ° |
| Room temperature heating circuit 2 | Modbus | ° |
| Room humidity heating circuit 2 | Modbus | % |
| Operating mode heating circuit 2 | Modbus | <v.0> |
| Heating requirement heating circuit 2 | Modbus | <v.0> |
| Target temperature heating circuit 3 | Modbus | ° |
| Room temperature heating circuit 3 | Modbus | ° |
| Room humidity heating circuit 3 | Modbus | % |
| Operating mode heating circuit 3 | Modbus | <v.0> |
| Heating requirement heating circuit 3 | Modbus | <v.0> |
| Boiler 1 temperature top | Modbus | ° |
| Boiler 1 operating mode | Modbus | ° |
| Puffer 1 temperature top | Modbus | ° |
| Puffer 1 temperature middle | Modbus | ° |
| Operating mode | Modbus | <v.1> |
| Outside temperature | Modbus | ° |
| Alarm 1 | Modbus | ° |
| Alarm 2 | Modbus | ° |
| Alarm 3 | Modbus | ° |
| Alarm 4 | Modbus | ° |
| Alarm 5 | Modbus | ° |
| Write target temperature heating circuit 1 | Modbus | ° |
| Write economy temperature heating circuit 1 | Modbus | ° |
| Write cooling requirements heating circuit 1 | Modbus | <v.1> |
| Write heating requirements heating circuit 1 | Modbus | <v.1> |
| Write flow target temperature heating circuit 1 | Modbus | ° |
| Write offset heating circuit 1 | Modbus | ° |
| Write operating mode heating circuit 1 | Modbus | <v.0> |
| Write target temperature heating circuit 2 | Modbus | ° |
| Write economy temperature heating circuit 2 | Modbus | ° |
| Write cooling requirements heating circuit 2 | Modbus | <v.1> |
| Write heating requirements heating circuit 2 | Modbus | <v.1> |
| Write flow target temperature heating circuit 2 | Modbus | ° |
| Write offset heating circuit 2 | Modbus | ° |
| Write operating mode heating circuit 2 | Modbus | <v.0> |
| Write target temperature heating circuit 3 | Modbus | ° |
| Write economy temperature heating circuit 3 | Modbus | ° |
| Write cooling requirements heating circuit 3 | Modbus | <v.1> |
| Write heating requirements heating circuit 3 | Modbus | <v.1> |
| Write flow target temperature heating circuit 3 | Modbus | ° |
| Write offset heating circuit 3 | Modbus | ° |
| Write operating mode heating circuit 3 | Modbus | <v.0> |
| Boiler 1 write target temperature | Modbus | ° |
| Boiler 1 write operating mode | Modbus | <v.1> |
| Puffer 1 write backup temperature | Modbus | ° |
| Puffer 1 write cooling temperature | Modbus | ° |
| External requirements | Modbus | <v.0> |
| External requirements temperature | Modbus | ° |
| Write operating mode | Modbus | <v.1> |