K Electric KE-P 5 Meter
Content languageEnglish
Description
The Modbus RTU meter provides an extremely effective means of integrating electrical measurements and metering functions into a Modbus network. With its support for the Modbus RTU protocol, this meter can seamlessly integrate into existing Modbus infrastructures, both in industrial and commercial environments.
The integration of the Modbus RTU meter involves establishing a communication link between the meter and other Modbus devices on the network. This is typically done through an RS-485 interface, which enables reliable and fast data transmission. By using the Modbus RTU protocol, data can be efficiently transferred, and device commands can be securely executed.
A significant advantage of integrating the Modbus RTU meter is its high compatibility with a variety of Modbus master devices such as PLCs (Programmable Logic Controllers), HMIs (Human Machine Interfaces), and SCADA (Supervisory Control and Data Acquisition) systems. This allows the meter to seamlessly integrate into existing automation and monitoring systems without requiring extensive modifications.
Furthermore, the Modbus RTU meter offers a wide range of measurement and metering functions, including voltage, current, and power measurements, as well as energy and power factor monitoring. These functions enable precise monitoring and measurement of electrical parameters in real-time, which is crucial for optimizing energy efficiency and process control.
The configuration and parameterization of the Modbus RTU meter are typically straightforward and user-friendly, as many manufacturers provide intuitive software tools and configuration applications. This allows users to quickly and easily adjust the necessary settings and commission the meter.
In summary, the Modbus RTU meter offers an excellent solution for integrating electrical measurements and metering functions into a Modbus network. With its high compatibility, extensive features, and ease of use, it is the ideal choice for applications where reliable and accurate capture of electrical parameters is required.
Inputs and outputs · 30
| Name | Type | Unit |
|---|---|---|
| Modbus Baudrate | Modbus | <v.1> |
| Modbus address | Modbus | <v.1> |
| Modbus Stopbit | Modbus | <v.1> |
| Modbus Parity | Modbus | <v.1> |
| System voltage L1-N | Modbus | V |
| System voltage L3-N | Modbus | V |
| System voltage L2-N | Modbus | V |
| Power factor (L1) | Modbus | <v.1> |
| Power factor (L2) | Modbus | <v.1> |
| Power factor (L3) | Modbus | <v.1> |
| Power factor (Σ) | Modbus | <v.1> |
| Residual leakage current | Modbus | A |
| Frequency | Modbus | Hz |
| Current (L3) | Modbus | A |
| Current (L2) | Modbus | A |
| Current (L1) | Modbus | A |
| System voltage (L3-L1) | Modbus | V |
| System voltage (L2-L3) | Modbus | V |
| System voltage (L1-L2) | Modbus | V |
| Active power (Σ) | Modbus | kW |
| Active power (Σ) | Modbus | kW |
| Active power (Σ) | Modbus | kW |
| Active power (L3) | Modbus | kW |
| Active power (L2) | Modbus | kW |
| Active power (L1) | Modbus | kW |
| Active power (Σ) | Modbus | kW |
| Apparent power (L1) | Modbus | kVA |
| Apparent power (L2) | Modbus | kVA |
| Apparent power (L3) | Modbus | kVA |
| Apparent power (Σ) | Modbus | kVA |
Ratings and comments
No ratings or comments yet.
Log in to rate, comment or ask a question. Log in