Template

iQntrol salt electrolysis SALT-COMPLETE

by PERAQUA Professional Water Products GmbHNo rating yet382 downloads

Content languageEnglish

Description

iQntrol SALT-COMPLETE is a high-precision disinfection system with intelligent pool management functions. The salt electrolysis ensures complete disinfection of the pool water. The SALT-COMPLETE salt electrolysis system measures the salt content and the redox value with a probe. It monitors the set pH value of the swimming pool water and adjusts the dosage to the changing ambient conditions. In addition, the salt system doses the set amount of algaecide daily in relation to the swimming pool volume.

Interfaces

- RS485

Functions Parameters can be transferred to the Loxone via RS485, writing is not possible for safety reasons The following values are transferred from the DOS-NET to Loxone

- ph actual value - ph target value - ORP actual value - ORP target value - Water temperature - Error code

RS485 settings

- Baud rate - 57600 bit/s - Number of data bits - 8 - Stop bits - 1 - Parity - None

Connection

Peraqua offers a complete sample program for the entire pool including integration: Ocean® filter pump, Aquastar Air backwash valve, level control either with float switch or pressure sensor, water treatment either liquid chlorine or salt electrolysis. The sample programming or the pump can be requested at [email protected]

Inputs and outputs · 8

NameTypeCommandUnit
03-04 pHComm\s2\2\1<v.2>
17 pH requiredComm\s16\1<v.1>
05-06 CL or RXComm\s4\2\1mV
18 CL or Rx requiredComm\s17\1mV
09-10 temperatureComm\s8\2\1<v.1>
11 error1Comm\s10\1<v>
24 error2Comm\s23\1<v>
02 unit typeComm\s1\1<v.2>

FAQ

No questions have been answered yet.

Ratings and comments

No ratings or comments yet.

Questions and answers

  1. Reading of status of relay

    Open

    Hello,

    Would be helpful to have possibility to read status of programable relay (heating for example) and reading of state of filtration pump. Is there any possibility?

    No replies

Report this entry

Report abuse

You have to be logged in to report an entry. Log in