iQntrol Dosieranlage DOS-COMPLETE Redox-CLF
Content languageEnglish
Description
Overview iQntrol DOS-COMPLETE is a high-precision disinfection system with intelligent pool management functions. Thanks to the four dosing pumps, disinfection, pH liquid, algaecide and flocculant can be dosed with one device. The touchscreen display shows all water quality information and makes it easy to set up the entire system. With the internet connection, you can monitor the parameters of your pool via a mobile and/or web application. The DOS-COMPLETE dosing system ensures crystal-clear water in your pool using the lowest possible quantities of chemical additives. The free chlorine or redox value is measured using a membrane probe or redox probe. It monitors the set pH value of the pool water and automatically adjusts the dosing to the changing ambient conditions. In addition, the dosing system doses the set amount of algaecide daily in relation to the swimming pool volume. The additional use of algaecide reduces the chlorine requirement. The slow, continuous dosing of flocculant binds even the smallest impurities and improves filter efficiency. Two versions available: REDOX measurement and free chlorine measurement CLF available
Interfaces RS485
Functions Parameters can be transferred to Loxone via RS485, writing is not possible for safety reasons The following values are transferred from the DOS-NET to Loxone
- ph actual value - ph target value - ORP/Cl actual value - ORP/Cl target value - Water temperature - Error code
RS485 settings
- Baud rate - 57600 bit/s - Number of data bits - 8 - Stop bits - 1 - Parity - None
Peraqua offers a complete sample program for the entire pool including integration: Ocean® filter pump, Aquastar Air backwash valve, level control either with float switch or pressure sensor, water treatment either liquid chlorine or salt electrolysis. The sample programming or the pump can be requested at [email protected]
Inputs and outputs · 8
| Name | Type | Command | Unit |
|---|---|---|---|
| 03-04 pH | Comm | \s2\2\1 | <v.2> |
| 17 pH required | Comm | \s16\1 | <v.1> |
| 05-06 CL or RX | Comm | \s4\2\1 | mV |
| 18 CL or Rx required | Comm | \s17\1 | mV |
| 09-10 temperature | Comm | \s8\2\1 | <v.1> |
| 11 error1 | Comm | \s10\1 | <v> |
| 24 error2 | Comm | \s23\1 | <v> |
| 02 unit type | Comm | \s1\1 | <v.2> |
FAQ
No questions have been answered yet.
Questions and answers
Werte stimmen nicht
OpenIch habe RS485 A/B/Ground korrekt angeschlossen. - Auch den Endwiderstand. Dennoch stimmen die gelieferten Werden nicht.
No replies
Log in to rate, comment or ask a question. Log in
Ratings and comments
No ratings or comments yet.