Hoval Energy Management
Content languageEnglish
Description
What is the aim of the Energy Management Template?
- Quite simply, we want to connect the Hoval Heatpump to an inverter like Solaredge or Fronius as easily as possible! - Quite secure, we don't want any faults on Hoval Heatpumps! The template is designed for operational safety.
What is the difference between the "Hoval Heating & Cooling Template" and the "Hoval Energy Management Template"? Operational safety
- The Heating & Cooling Template is a full integration of the Hoval system in Loxone. - The Heating & Cooling Template´s logic is responsible for the correct flow temperatures in the heating circuits and regulates the hot water temperature based on the logic. - If there are problems in the Heating & Cooling Template logic, the heating circuits or hot water preparation may be under- or oversupplied. - With the energy management template, we transmit a switch-on recommendation to the Hoval Heatpumps - If there are problems in the Energy Management Templates´s logic, the heating circuits and the hot water work just as reliably as before!
Hoval with the TopTronic® E operating system can be connected to Loxone via multiple HovalConnect Gateways (GW). Please note that, starting in July 2026, we have enabled all Hoval gateways—whether "LAN", "Wi-Fi", "Modbus", "OPCUA", or "KNX" —to support the Modbus interface via an over-the-air update from HovalConnect. The RTU terminal block is included on the HovalConnect Modbus Gateway (article number 6049501) as standard, or can be ordered optionally from Hoval (article number 2062935). If you only need cost-effective integration via Modbus TCP, the HovalConnect LAN Gateway (article number 6049496) is sufficient! This means that all existing systems and new Hoval systems come with Loxone connectivity right out of the box, so there’s no need to purchase any additional hardware!
There are four different ways how to connect Hoval with Loxone: 1.Hoval Modbus TCP
2.Hoval Modbus RTU Gateway with Loxone Modbus Extension
3.Hoval Modbus RTU Gateway with a Loxone Modbus Air.
4.Hoval Modbus RTU Gateway with a Loxone Modbus Tree.
Depending on variation of your project you can choose between Miniserver, Miniserver Go or Miniserver Compact The Hoval TopTronic E (TTE) is a operating system for Hoval District Heating, Air/Water, Brine/Water, Water/Water Heatpumps, Gas, Oil and wood sources that are able to heat or cool by stand alone or combining them to hybridsystems.
The Hoval Top Tronic E (TTE) is also able to operate his own Ventilation System. The Hoval Top Tronic E (TTE) is also able to communicate with the Hoval PV-Heater. The Hoval Top Tronic E (TTE) is is also controllable in a full integration with the Heating & Cooling Template.
The choice of paring Hoval Systems with Loxone over the Energy Management Template offers the possibility of:
- Communication with PV systems: Active integration in interaction with e.g. PV- Systems in a Loxone Energy Management - Reliability: Reliable datapoint selection so that the heatpump system cannot be impaired in its normal operation in the event of failure or malfunction. - Protection against constant switching on and off: The exclusive use of preferred operation and the use of a PV heating rod significantly reduces the heat pump's cycles and increases the service life of the system! - We are already taking care of: If you transmit excessive setpoints for the heating buffer cylinder or the heating circuits, but it is warm outside and there is no need for heating, the heat pump will NOT execute the offset setpoints! It knows the “heating limit” and the “outside temperature” into account, so to speak. - Analyzes: Use statistics or individual notifications to use Loxone as an analysis tool - Visualization: Create individual system schematics to use Loxone as a visualization tool
How to:
Structure:
System overview example using Modbus TCP:
Hoval helpcenter, download area and activation of Modbus:
- If you need help with e.g. the configuration of Modbus within the Hoval Control unit please contact our local departments. - Hoval Integrate CH ([email protected]) - Hoval Integrate AT ([email protected]) - Hoval Integrate DE ([email protected]) - You have to use the direct download of documents on the Hoval Homepage. Therefore, the instructions in the download area of the template must be used and checked for the latest version. - To activate Modbus TCP on the Control unit of your Hoval Source, please follow the Modbus TCP instructions e.g. "Praxisanleitung Modbus Hoval Loxone" in the download area of the template. Please always use the following link Modbus datapoint list for a actual modbus documentation! - In addition to the datapoints of the UseCase to the Download Button, a english template of datapoints is also available in the download area of the Librarytemplate. - Please use the attached PDF document with “Hoval Integrate Leistungsdaten für Energiemanagement” to obtain setting recommendations for the Loxone energy manager building block. - For Remote Support reasons trough Hoval SmartServices and automatic software updates (Bugfixings & new datapoints) of the Gateway, please connect your HovalConnect Gateway with HovalConnect.
Example UseCase: Integration of a Hoval TTE: Residential building with Heatpump, Combined Hot Water / Heating Buffer, Heating circuit 1 +2
- Device Air/Water (Heatpump Belaria pro comfort) --> Controlled by Hoval! - Heating Buffer & Hot water storage tank (EnerVal) --> Controlled by Hoval! - Mixing circuit heating/cooling MK1 e.g. HC1 (underfloor heating) --> Controlled by Hoval! - Mixing circuit heating/cooling MK2 e.g. HC2 (cealing heating) --> Controlled by Hoval!
Inputs and outputs · 54
| Name | Type | Unit |
|---|---|---|
| Aktuelle Vorlauftemperatur HC2 [VF2] | Modbus | °C |
| Status Betriebsart HC2 | Modbus | <v> |
| Aktuelle Warmwasserspeichertemperatur Oben [SF1] | Modbus | °C |
| Status Warmwasserspeicher Betriebsart | Modbus | <v> |
| Status Warmwasserspeicher Solltemperatur | Modbus | °C |
| Status Betriebsart HC1 | Modbus | <v> |
| Aktuelle Vorlauftemperatur HC1 [VF1] | Modbus | °C |
| Status Erzeuger Solltemperatur | Modbus | °C |
| Aktuelle Erzeugervorlauftemperatur [CVF] | Modbus | °C |
| Status Erzeuger Betriebsmeldung | Modbus | <v> |
| Aktuelle Regelstrategie HC1 | Modbus | <v> |
| Aktuelle Regelstrategie HC2 | Modbus | <v> |
| Aktuelle Außentemperatur [AF1] | Modbus | °C |
| Aktuelle Warmwasserspeichertemperatur Unten [SF2] | Modbus | °C |
| Aktuelle Puffertemperatur Oben [PF1] | Modbus | °C |
| Aktuelle Pufferisstemperatur Unten [PF2] | Modbus | °C |
| Status Pufferspeicher Betriebsart | Modbus | <v.1> |
| Status Pufferspeicher Solltemperatur | Modbus | °C |
| Status Elektrische Gesamtenergie | Modbus | MWh |
| Status Thermische Gesamtenergie Heizbetrieb | Modbus | MWh |
| Status Thermische Gesamtenergie Warmwasserbetrieb | Modbus | MWh |
| Status Thermische Gesamenergie Kühlbetrieb | Modbus | MWh |
| Aktuelle elektrische Leistung | Modbus | kW |
| Aktuelle thermische Leistung | Modbus | kW |
| Status Vorlaufsolltemperatur HC1 | Modbus | °C |
| Status Vorlaufsolltemperatur HC2 | Modbus | °C |
| Status Fehlercode vom Automaten | Modbus | <v> |
| Status Mischkreispumpe HC1 | Modbus | <v> |
| Status Mischkreispumpe HC2 | Modbus | <v> |
| Status Mischer HC1 | Modbus | % |
| Status Mischer HC2 | Modbus | % |
| Status Wärmeerzeuger | Modbus | <v.1> |
| Aktuelle Modulation WP | Modbus | % |
| Status Betriebsstunden | Modbus | h |
| Status Schaltzyklen | Modbus | <v.0> |
| Aktuelle HZ Puffer WPF Fühler Temperatur [WPF] | Modbus | °C |
| Status Betriebsart HC3 | Modbus | <v> |
| Aktuelle Vorlauftemperatur HC3 [VF3] | Modbus | °C |
| Status Mischkreispumpe HC3 | Modbus | <v> |
| Status Vorlaufsolltemperatur HC3 | Modbus | °C |
| Status Mischer HC3 | Modbus | % |
| Aktuelle Regelstrategie HC3 | Modbus | <v> |
| Aktuelle Rücklauftemperatur | Modbus | °C |
| Status Jahresarbeitszahl | Modbus | <v.1> |
| Aktueller Volumenstrom | Modbus | l/min |
| Aktueller COP | Modbus | <v.1> |
| Status Detailstatus Wärmepumpe | Modbus | <v.1> |
| Smart Grid Auslösen | Modbus | <v> |
| Smart Grid Offset Warmwasser Soll | Modbus | °C |
| Smart Grid Offset Heizungspuffer Soll | Modbus | °C |
| Smart Grid Offset Raum Soll HC1 | Modbus | °C |
| Smart Grid Offset Raum Soll HC2 | Modbus | °C |
| Smart Grid Offset Raum Soll HC3 | Modbus | °C |
| Smart Grid über Systembus | Modbus | <v> |
FAQ
No questions have been answered yet.
Questions and answers
Kann nur auslesen, aber keine Offsetwerte übermitteln.
OpenHallo,
An was kann es liegen wenn die Smart Grid Offsetwerte nicht an der Hoval Regelung ankommen bzw. Smart Grid gar nicht auslösen lässt?
1 reply
Möglicher Grund 1: Für "ältere" Modbus Gateways [GW] und "WEZ" Reglermodule [WEZ] ist gegebenenfalls ein Softwareupdate notwendig. Diese Updates am Gateway [GW] geschehen automatisch, WENN das Gateway in Hoval Connect registriert wurde bzw. fest am LAN angebunden ist..! Diese Updates können alternativ auch durch den Hoval Werkskundendienst ausgeführt werden.
Möglicher Grund 2: Der "Hoval PV Smart Energiemanager" war zuvor aktiv und überschreibt den Sollwert der von Loxone übermittelt wird sofort wieder. Dieser muss in der Serviceebene deaktiviert werden und die WEZ Zieladressen müssen von Adresse 1 auf Adresse 16 verstellt werden.
Wer das NICHT machen möchte, kann auch die Raumtemperaturen der Heizkreise oder die Warmwassertemperatur schreiben. Datenpunkt HC1: 1481 (Range 10-30°C) Datenpunkt HC2: 1483 (Range 10-30°C) Datenpunkt HC3: 1485 (Range 10-30°C) Warmwasser: 1497 (Range 10-60°C)
Die Verschiebung der Raumtemperaturen haben eine Verschiebung der Heizkurve und somit einer Verschiebung der Vorlauftemperatur zur Folge. Hängt ein Pufferspeicher (Egal ob mit PF oder WPF Fühlern) in dieser Regelkette, so wird dieser AUTOMATISCH in seiner Temperatur mit nach oben gezogen und macht ca. 3 Kelvin mehr, als der höchste Vorlaufsollwert der Heizkreise.
Kühlen Fehlt im Template
OpenIm Template ist der Kühlfall nicht beschrieben, was gilt es in diesem Fall zu beachten?
1 reply
Hallo,
Der Kühlfall wurde bewusst NICHT berücksichtigt. Der Grund dafür ist, dass immer wenn die Wärmepumpe automatisch in den Kühlbetrieb geht, ein PV Überschuss vorhanden ist. Da bei Hoval überwiegend Luft/Wasser Wärmepumpen zum Einsatz kommen, haben diese im Kühlbetrieb auch immer sehr gute "Quellentemperaturen" bzw. Außentemperaturen. Daher ist die elektrische Leistungsaufnahme besonders gering im Kühlfall und bedarf keinem Energiemanagement.
Für Anlagen außerhalb des Regelfalls, die trotzdem Kühlen möchten, empfehlen wir eine Konstante Vorlauftemperaturregelung mit dezentraler Taupunktüberwachung auf Raumebene, wie wir es im Webinar bzw. "Heating & Cooling Template" beschrieben haben.
In diesem Fall wäre es notwendig, die Regelstrategie des Heizkreises auf "Konstant" zu setzen (Datenpunkt 27510 für HC1) und eine Konstante Vorlauftemperatur für den Kühlfall schreiben (Datenpunkt 19482 für HC1).
Die berechnete Taupunkttemperatur der Räume begrenzt die "Minimale" Vorlauftemperatur nach "Unten". Wer keine Taupunkttemperatur berechnen kann, sollte die Minimale Kühlvorlauftemperatur von 18°C nicht unterschreiten, da es sonst zur Kondenswasserbildung kommen kann.
How To --> Im Downloadbereich des Heating & Cooling Templates ist dieser UseCase in einem Muster Config File beschrieben.
Support
OpenJede Hoval Anlage ist individuell. Wer unterstützt mich seitens Hoval bei Modbus, Datenpunkten, Softwareupdates und Funktionserklärungen?
1 reply
Hoval hat sich zum Dezember 2025 mit einem eigenen Support für externe Energie- & Home-Automation Systeme wie Loxone ausgerichtet.
Sie sind Endkunde, Elektriker, Systemintegrator oder Installateur? Dann melden Sie sich gerne in Ihrer Hoval Ländergesellschaft.
Ein Team aus Service- & MSR-Techniker unterstützt Sie bei Ihren Vorhaben.
Hoval Integrate CH --> https://www.hoval.ch/de_CH/hoval-integrate-landing-page ([email protected]) Hoval Integrate AT --> https://www.hoval.at/de_AT/hoval-integrate-landing-page ([email protected]) Hoval Integrate DE --> https://www.hoval.de/de_DE/hoval-integrate-landing-page ([email protected])
Modbus Schnittstellenaktivierung funktioniert nicht
OpenHallo,
Ich habe leider nur ein LAN Gateway, kann zwar am Hoval Display den Menüpunkt "Modbus" auswählen, es erscheinen aber keine Modbus Einstellparameter wie Protokoll (TCP oder RTU), Baudrate oder Parität.
An was kann das liegen?
Benötige ich nun extra ein HovalConnect Modbus Gateway?
1 reply
Hallo,
Über die Aufschaltung bzw. Registrierung der Anlage bei HovalConnect erhält das HovalConnect Gateway over the air automatisch Softwareupdates.
Im letzten Softwareupdate (Release Juli 2026) mit der Softwareversion 2.39.XX haben wir die Modbus Schnittstelle an allen HovalConnect Gateways (LAN, WLAN, KNX, OPCUA) freigeschaltet.
Das bedeutet Hoval Bestandsanlagen haben über das kostenlose Softwareupdate eine Modbus Schnittstelle erhalten und können ohne dem Einsatz eines teureren HovalConnect Modbus Gateway mit Loxone Miniserver gekoppelt werden.
Nach dem Softwareupdate werden also die Parameter im Menüpunkt "Modbus" sichtbar und es wird lediglich ein kosteneffizientes "LAN" Gateway benötigt, um die Konnektivität mit Loxone herzustellen.
Hoval ermöglicht durch die schnittstellenoffene Strategie über Hoval Integrate also die Konnektivität mit PV-Anlagen, Batteriespeicher, Wallboxen, PV-Heizstäben, dynamischen Stromtarifen, Netzdienlicher Steuerung (§14a), Lastmanagement, Energiegemeinschaften, Einzelraumregelungen, Bedarfsgeführter Erzeugung, Wettereinflüsse, Virtuellen Kraftwerken und vieles mehr!