Hargassner boiler control
Content languageEnglish
Description
The Modbus Plugin for every Hargassner touch-control boiler.
In case you have trouble with the plugin or with the connection to your boiler, please contact [email protected] or +43/7723/5274 - 400
Inputs and outputs · 48
| Name | Type | Unit |
|---|---|---|
| Accumulator Temperatur Bottom | Modbus | °C |
| Accumulator Temperatur Middle | Modbus | °C |
| Accumulator Temperatur Top | Modbus | °C |
| Boiler Output | Modbus | % |
| Boiler temp. | Modbus | °C |
| Boiler temp. - set value | Modbus | °C |
| Return temperature | Modbus | <v.1> |
| Set value - return temp. | Modbus | <v.1> |
| Accum. fill level | Modbus | <v.1> |
| Highest demand | Modbus | <v.1> |
| Temp. - external heat | Modbus | <v.1> |
| Current error number | Modbus | <v.1> |
| Fuel storage level | Modbus | <v.1> |
| Outside temperature | Modbus | <v.1> |
| Outside temp. - average | Modbus | <v.1> |
| External heat circuit target temp. | Modbus | <v.1> |
| Temp. - flow - heat circuit A | Modbus | <v.1> |
| Set temp. - flow - heat circuit A | Modbus | <v.1> |
| Room sensor - remote control - HC A | Modbus | <v.1> |
| Set temp. - room sensor - heat circuit A | Modbus | <v.1> |
| Status - HC A | Modbus | <v.1> |
| Remote Status - HC A | Modbus | <v.1> |
| Room temp. spec. for HC A | Modbus | <v.1> |
| Temp. - flow - heat circuit 1 | Modbus | <v.1> |
| Set temp. - flow - heat circuit 1 | Modbus | <v.1> |
| Room sensor - remote control - HC 1 | Modbus | <v.1> |
| Set temp. - room sensor - heat circuit 1 | Modbus | <v.1> |
| Status - HC 1 | Modbus | <v.1> |
| Remote Status - HC 1 | Modbus | <v.1> |
| Room temp. spec. for HC 1 | Modbus | <v.1> |
| Temperature HWT A | Modbus | <v.1> |
| HWT A target temperature | Modbus | <v.1> |
| HWT A status | Modbus | <v.1> |
| Temperature HWT 1 | Modbus | <v.1> |
| HWT 1 target temperature | Modbus | <v.1> |
| HWT 1 status | Modbus | <v.1> |
| MBUS channel 1 flow temperature | Modbus | <v.1> |
| MBUS channel 1 return temperature | Modbus | <v.1> |
| MBUS channel 1 output | Modbus | <v.1> |
| MBUS channel 1 flow | Modbus | <v.1> |
| MBUS channel 1 energy | Modbus | <v.1> |
| Malfunction | Modbus | % |
| Pump - HC A | Modbus | <v.1> |
| Pump - HC 1 | Modbus | <v.1> |
| HWT A pump | Modbus | <v.1> |
| HWT 1 pump | Modbus | <v.1> |
| HWT A circulation pump | Modbus | kW |
| HWT 1 circulation pump | Modbus | kW |
FAQ
No questions have been answered yet.
Questions and answers
Probleme Anbindung HKR Touch
OpenHallo, trotz aktivierter ModBus Schnittstelle un dem Umstand das ich auch Werte problemlos lesen kann schaffe ich es nicht der HKR Touch die Vorlauftemperatur für den HK1 mitzuteilen.
Leider finde ich auch keine spezifische Anleitung wie man das mit welchen Parametern und Werten einrichtet.
Wenn ich den Wert 6999 aus dem Loxone PlugIn nehme dann nimmt er den Wert mit einen ACK an aber er passt die Vorlauftemperatur nicht an.
Wenn ich hier aus dem Template Temp. - flow - heat circuit 1 10144 nehme und dort den Wert hinschicke bekomme ich kein ACK zurück und er passt den Wert auch nicht an.
Auf dem HKR habe ich als Fernbedienung Modbus aktiviert.
Danke.