EnergyFace
Content languageEnglish
Description
Connection of the EnergyFace unit for the control of solar panels and the hot water storage tank.
Replace the string "_DEVICE_ID_" in the URL with your unit serial number.
The EFx422 control unit is equipped with a program for controlling a solar system, pool heating, automatic boiler or boiler / stove with manual application. EFx422 is a modern control unit with simple setup and with the possibility of access via the Internet in the basic price at no extra charge, which brings easy setup, control and service of heating and solar systems. The regulation is PROPULS SOLAR and is manufactured in the Czech Republic.
What the EFx422 control offers you:
- Easy installation and adjustment of the control via mobile devices
- Built-in WiFi as standard for Internet access
- Easy service and adjustment of settings for assembly companies thanks to access via the Internet and stored measurement history
- Measurement and display of up to 7 temperatures - uses Pt1000 sensors and data sensors
- Switching of up to 4 outputs - control of pumps and valves
- 8 control schemes for solar system control (1 or 2 collector arrays, up to 2 storage tanks, pool heating with filtration control)
- Additional control diagrams for the control of an automatic boiler or a boiler / stove with manual application
- Pool heating: timer for filtering run, function of pool heating priority before time program
- "Anti-freeze" and "Cooling" functions
- Detection of flow restriction by filter clogging or aeration
- Calculation of heat produced by a solar system
- Graphs with the history of temperatures and the amount of heat produced (days, months, years)
- Regulation manufactured and developed in the Czech Republic
The package includes 1 temperature sensor for solar collectors and 1 digital temperature sensor for measuring the water temperature in the tank. Additional sensors can be purchased, for example, for measuring the heat produced, measuring the upper temperature of the storage tank or measuring the temperature of the second field of solar collectors. Display of up to 7 temperatures.
Documentation only in CZ.
Samples from the control administration.
Inputs and outputs · 15
| Name | Type | Command | Unit |
|---|---|---|---|
| TMP_D1 | VirtualInHttp | <T_D1>\v °C | |
| TMP_D2 | VirtualInHttp | <T_D2>\v °C | |
| TMP_D3 | VirtualInHttp | <T_D3>\v °C | |
| TMP_D4 | VirtualInHttp | <T_D4>\v °C | |
| TMP_D5 | VirtualInHttp | <T_D5>\v °C | |
| TMP_D6 | VirtualInHttp | <T_D6>\v °C | |
| TMP_D7 | VirtualInHttp | <T_D7>\v °C | |
| TMP_D8 | VirtualInHttp | <T_D8>\v °C | |
| MIX_VALVE | VirtualInHttp | <PSCH7>\v % | |
| TMP_COLLECTOR | VirtualInHttp | <T_K>\v °C | |
| UPDATE_DATE | VirtualInHttp | <LastDate>\v | |
| UPDATE_TIME | VirtualInHttp | <LastTime>\v | |
| EST_PERFORMANCE | VirtualInHttp | <Vykon>\v | |
| PUMP_1 | VirtualInHttp | <O1>\v | |
| PUMP_2 | VirtualInHttp | <O2>\v |