DEYE SUN 12 Inverter
Content languageEnglish
Description
Basic input registers of a DEYE SUN 12 inverter over modbus.
Modbus extention setup: Modbus rate: 9600 Stop bits: 1 Parity: None Timing: Auto
In the example Config File in Additonal Downloads an example application of these templates is shown
Inputs and outputs · 46
| Name | Type | Unit |
|---|---|---|
| PV1 input power | Modbus | kW |
| PV2 input power | Modbus | kW |
| PV3 input power | Modbus | kW |
| PV4 input power | Modbus | kW |
| DC Voltage 1 | Modbus | V |
| DC Voltage 2 | Modbus | V |
| DC Voltage 3 | Modbus | V |
| DC Voltage 4 | Modbus | V |
| Inverter Output Total Power | Modbus | kW |
| Grid Side Total Power | Modbus | kW |
| Battery power flow | Modbus | kW |
| Battery temperature | Modbus | °C |
| Battery Voltage | Modbus | V |
| Battery SOC | Modbus | % |
| Load Total Power | Modbus | kW |
| Run State | Modbus | <v> |
| Battery Total Charge | Modbus | kWh |
| Battery Total Discharge | Modbus | kWh |
| Grid charge | Modbus | <v> |
| Solar sell | Modbus | <v> |
| TP1 Grid charge enabled | Modbus | <v> |
| TP2 Grid charge enabled | Modbus | <v> |
| TP3 Grid charge enabled | Modbus | <v> |
| TP4 Grid charge enabled | Modbus | <v> |
| TP5 Grid charge enabled | Modbus | <v> |
| TP6 Grid charge enabled | Modbus | <v> |
| TP1 Capacity | Modbus | % |
| TP2 Capacity | Modbus | % |
| TP3 Capacity | Modbus | % |
| TP4 Capacity | Modbus | % |
| TP5 Capacity | Modbus | % |
| TP6 Capacity | Modbus | % |
| Grid charge | Modbus | <v> |
| Solar sell | Modbus | <v> |
| TP1 Grid charge enabled | Modbus | |
| TP2 Grid charge enabled | Modbus | |
| TP3 Grid charge enabled | Modbus | |
| TP4 Grid charge enabled | Modbus | |
| TP5 Grid charge enabled | Modbus | |
| TP6 Grid charge enabled | Modbus | |
| TP1 Capacity | Modbus | % |
| TP2 Capacity | Modbus | % |
| TP3 Capacity | Modbus | % |
| TP4 Capacity | Modbus | % |
| TP5 Capacity | Modbus | % |
| TP6 Capacity | Modbus | % |
FAQ
No questions have been answered yet.
Questions and answers
How to plug in SUN 10K?
OpenWhat port are you plugging into on the Deye? Modebus? And what is the pinout? Thank you
2 replies
in den BMS Port, Ader 1 und 2 oder 7 und 8.
Geht auch im RS485 Port Ader 1 & 2
Modbus Air Extension
OpenHello, thank you very much for the library, I tried to receive the data with the Modbus Air interface, unfortunately I get no data. Is it possible that this is not possible? Which interface does the device have to be connected to exactly, the Modbus or the BMS interface?
Does the Modbus interface have to be activated? Or is a specific firmware required?
1 reply
It works now, you had to go to Slave in the WR under Advanced Settings and set the address from 00 to 01, then the Modbus Air received the data immediately.
How to connect ModBus communication with SUN 6K (10K)?
OpenI have a LIFEPO4 battery communication with AKUBOX connected to the BMS port, I have an Eastron SDM630 connected to the Meter-485 port. Is it possible to connect a Modbus extension to Modebus ? Or how would you solve it ?
No replies
CRC Errors Using Loxone's Deye SUN 12K SG04LP3 Library
OpenI am using the Loxone-provided library for the Deye SUN 12K SG04LP3 inverter and have encountered intermittent CRC errors when communicating via Modbus RTU. These errors do not appear consistently but occur frequently enough to cause concern.
Could you please advise on possible causes and solutions for these CRC errors? Are there any recommended settings, firmware updates, or troubleshooting steps I should follow?
No replies
CRC Errors Using Loxone's Deye SUN 12K SG04LP3 Library
OpenI am using the Loxone-provided library for the Deye SUN 12K SG04LP3 inverter and have encountered intermittent CRC errors when communicating via Modbus RTU. These errors do not appear consistently but occur frequently enough to cause concern.
Could you please advise on possible causes and solutions for these CRC errors? Are there any recommended settings, firmware updates, or troubleshooting steps I should follow?
No replies
Does it work with Modbus TCP?
OpenA Modbus extension is needed, or it also works via Modbus TCP (with a connected DEYE LSE-3 Stick logger)?
1 reply
It works without a modbus extension via MODBUS TCP. Set the inverter as SLAVE and adress to 01 (not 00) and use port 8899 instead of the standard 502 for MODBUS TCP communication. Thus it works fine for me with the LSE-3 Logger.
Modbus TCP
OpenDo you know if it's possible to work also ModBUS TCP with the WIFI logger? or only with the LAN logger? I have a wifi loger, I set slave and 01 address modbus, on 8899 port, but i did not receive data; thank you
No replies
Compatiblity
OpenHello is it with Deye Hybrid-Wechselrichter SUN-20K-SG05LP3-EU-SM2 20 kW 3 Phasen 48V Compatible and modbus tcp?
Do i need extra Hardware? Thanks in advice
No replies
Log in to rate, comment or ask a question. Log in
Ratings and comments
Edgaras Rudko
Rated 5 of 5★★★★★
Thank you for template saved a lot of time. everything is working out of the box.
Log in to rate, comment or ask a question. Log in