DeDietrich Diematic Evolution
Content languageEnglish
Description
Electronic control system VM DIEMATIC EVOLUTION built into the wall cabinet, allows control of up to 3 heating circuits and 2 HW circuits, each of the heating circuits can be a direct circuit or a circuit with a mixing three-way motorized valve 230 V. Modbus RTU integration is possible using the GTW-08 addon module.
- Mode control - Outlet water temp control - Error tracking
Inputs and outputs · 100
| Name | Type | Unit |
|---|---|---|
| 273_FlowTempRec | Modbus | <v.1> |
| 274_ReturnTempRec | Modbus | <v.1> |
| 275_ProducerManagerStatusBitfieldReceived | Modbus | <v.1> |
| 276_ProducerManagerRequestReceived | Modbus | <v.1> |
| 279_ApplianceStatus1 | Modbus | <v.1> |
| 280_ApplianceStatus2 | Modbus | <v.1> |
| 384_ApTOutside | Modbus | °C |
| 385_ApSeasonMode | Modbus | <v> |
| 400_ApTflow | Modbus | °C |
| 401_ApTreturn | Modbus | <v.1> |
| 403_HpHeatPumpTF | Modbus | °C |
| 404_HpHeatPumpTR | Modbus | °C |
| 409_ApWaterPressure_ | Modbus | bar |
| 389_ApForceSummerMode | Modbus | <v.1> |
| 1108_ZoneCurrentMode | Modbus | <v.1> |
| 278_Appliance Error Priority | Modbus | <v.1> |
| 502_parApCoolingEnabled | Modbus | <v.1> |
| 661_parZoneAmbiantCoolingNightSetpoint | Modbus | <v.1> |
| 676_parZoneHCZPN 8-1 | Modbus | <v.1> |
| 677_parZoneMaxPreHeatTime | Modbus | <v.1> |
| 687_parZonePumpPostRun | Modbus | min |
| 688_parZoneTimeProgramSelected | Modbus | <v.1> |
| 1620_Current zone mode: | Modbus | <v.1> |
| 503_ApCoolingForced | Modbus | <v.1> |
| 531_varApplianceOnError | Modbus | <v.1> |
| 533_ErroPriority1 | Modbus | <v.1> |
| 641_parZoneFunction | Modbus | <v.1> |
| 649_parZoneMode | Modbus | <v.1> |
| 650_parZoneRoomUserActivitySetpoint1 | Modbus | °C |
| 651_parZoneRoomUserActivitySetpoint2 | Modbus | <v.1> |
| 655_parZoneAmbiantNightSetpoint | Modbus | <v.1> |
| 656_parZoneRoomCoolingSetpoint1 | Modbus | <v.1> |
| 657_parZoneRoomCoolingSetpoint2 | Modbus | <v.1> |
| 662_parZoneAmbiantHolidaySetpoint | Modbus | °C |
| 664_parZoneRoomManualSetpoint | Modbus | <v.1> |
| 671_parZoneHeatingControlStrategy | Modbus | <v.1> |
| 672_parZoneTFlowSetpointMax | Modbus | °C |
| 673_parZoneTFlowCoolingMixingSetpoint | Modbus | <v.1> |
| 674_parZoneSlope | Modbus | <v.1> |
| 675_parZoneHCZPD 8-1 | Modbus | <v.1> |
| 1102_varZoneTRoomSetpoint 8-1 | Modbus | °C |
| 1179_Required Hot Water Temperature (Holiday) | Modbus | <v.1> |
| 1180_Required Hot Water Temperature for Antilegionella | Modbus | <v.1> |
| 1184_Maximum temperature Hot Water | Modbus | <v.1> |
| 1200_Time program selected for Hot Water | Modbus | <v.1> |
| 1619_Current zone activity: | Modbus | <v.1> |
| 1103_varZoneTOutside 8-1 | Modbus | °C |
| 1104_varZoneTRoom 8-1 | Modbus | °C |
| 1107_varZoneCurrentActivities | Modbus | <v.1> |
| 1161_Hot water operating mode | Modbus | <v.1> |
| 1177_Required Hot Water Temperature (Comfort) | Modbus | <v.1> |
| 1178_Required Hot Water Temperature (Reduced) | Modbus | <v.1> |
| 410_varApFlowmeter 8 -1 | Modbus | l/min |
| 411_varApStatus | Modbus | <v.1> |
| 412_varApSubStatus | Modbus | <v.1> |
| 406_varChSetpoint 8 -1 | Modbus | °C |
| 405_varApInternalSetpoint 8 -1 | Modbus | °C |
| 407_varHpCoolingSetpoint 8 -1 | Modbus | °C |
| 388_parApFrostMinToutside | Modbus | <v.1> |
| 387_parApNeutralBandSummerWinter | Modbus | <v.1> |
| 386_parApSummerWinter | Modbus | <v.1> |
| 1631 - Hot water temperature (lower sensor) | Modbus | <v.1> |
| 1632 - Hot water temperature (upper sensor) | Modbus | <v.1> |
| 389_ApForceSummerMode | Modbus | |
| 688_parZoneTimeProgramSelected | Modbus | <v.1> |
| 503_ApCoolingForced | Modbus | |
| 1161_Hot water operating mode | Modbus | <v.1> |
| 386_parApSummerWinter | Modbus | <v.1> |
| 662_parZoneAmbiantHolidaySetpoint | Modbus | <v.1> |
| 676_parZoneHCZPN 8-1 | Modbus | <v.1> |
| 677_parZoneMaxPreHeatTime | Modbus | <v.1> |
| 687_parZonePumpPostRun | Modbus | <v.1> |
| 1177_Required Hot Water Temperature (Comfort) | Modbus | <v.1> |
| 1178_Required Hot Water Temperature (Reduced) | Modbus | <v.1> |
| 1179_Required Hot Water Temperature (Holiday) | Modbus | <v.1> |
| 1180_Required Hot Water Temperature for Antilegionella | Modbus | <v.1> |
| 1184_Maximum temperature Hot Water | Modbus | <v.1> |
| 1200_Time program selected for Hot Water | Modbus | <v.1> |
| 256_PowerSetpoint | Modbus | <v.1> |
| 257_TemperatureSetpoint | Modbus | <v.1> |
| 258_AlgoritthmType | Modbus | <v.1> |
| 259_HeatDemandtype | Modbus | <v.1> |
| 387_parApNeutralBandSummerWinter | Modbus | <v.1> |
| 388_parApFrostMinToutside | Modbus | <v.1> |
| 502_parApCoolingEnabled | Modbus | <v.1> |
| 649_parZoneMode | Modbus | <v.1> |
| 650_parZoneRoomUserActivitySetpoint1 | Modbus | <v.1> |
| 651_parZoneRoomUserActivitySetpoint2 | Modbus | <v.1> |
| 655_parZoneAmbiantNightSetpoint | Modbus | <v.1> |
| 656_parZoneRoomCoolingSetpoint1 | Modbus | <v.1> |
| 657_parZoneRoomCoolingSetpoint2 | Modbus | <v.1> |
| 661_parZoneAmbiantCoolingNightSetpoint | Modbus | <v.1> |
| 664_parZoneRoomManualSetpoint | Modbus | <v.1> |
| 671_parZoneHeatingControlStrategy | Modbus | <v.1> |
| 672_parZoneTFlowSetpointMax | Modbus | <v.1> |
| 673_parZoneTFlowCoolingMixingSetpoint | Modbus | <v.1> |
| 674_parZoneSlope | Modbus | <v.1> |
| 675_parZoneHCZPD 8-1 | Modbus | <v.1> |
| 500_parApChEnabled | Modbus | |
| 501_parApDhwEnabled | Modbus |
FAQ
No questions have been answered yet.
Questions and answers
Wrong correcrtion in the template
OpenHi, one partner has noticed, that there is a mistake in this template.
257_TemperatureSetpoint Corection is wrong, could you please clarify this?
No replies