BWT Perla
Content languageEnglish
Description
This HTTP Virtual-In template enables retrieving very useful data about BWT water softener devices of the Perla series into a Loxone project. Note: BWT AQA (blue cover) are not supported!
Device Setup
- BWT Perla device must be connected to (W-)LAN network - API enabled Firmware must be requested from BWT (free-of-charge) - planned release by BWT in Q1/2024 - Device must be registered in BWT App - the confirmation email contains the password to connect to the device - assign a fixed IP address for the BWT device, either in your network router's DHCP settings or on the BWT device itself - Insert the received password and the IP address of the device into the connect URL (username is always "user"): http://user:<PASSWORD>@<IP-ADDRESS>:8080/api/GetCurrentData
To meter the water consumption the VI "BlendedWaterSinceSetup_l" can be connected to a Meter block's "Mr" input:
Inputs and outputs · 26
| Name | Type | Command | Unit |
|---|---|---|---|
| OutOfService | VirtualInHttp | "OutOfService" : \v | <v> |
| RegenerativLevel | VirtualInHttp | "RegenerativLevel" : \v | % |
| RegenerativRemainingDays | VirtualInHttp | "RegenerativRemainingDays" : \v | Tage |
| BlendedWaterSinceSetup_l | VirtualInHttp | "BlendedWaterSinceSetup_l" : \v | l |
| CapacityColumn1_ml_dH | VirtualInHttp | "CapacityColumn1_ml_dH" : \v | ml*°dH |
| CapacityColumn2_ml_dH | VirtualInHttp | "CapacityColumn2_ml_dH" : \v | ml*°dH |
| CurrentFlowrate_l_h | VirtualInHttp | "CurrentFlowrate_l_h" : \v | l/h |
| DosingSinceSetup_ml | VirtualInHttp | "DosingSinceSetup_ml" : \v | ml |
| FirmwareVersion | VirtualInHttp | "FirmwareVersion" : "\v" | <v.4> |
| HardnessIN_CaCO3 | VirtualInHttp | "HardnessIN_CaCO3" : \v | ppm CaCO³ |
| HardnessIN_fH | VirtualInHttp | "HardnessIN_fH" : \v | °fH |
| HardnessIN_dH | VirtualInHttp | "HardnessIN_dH" : \v | °dH |
| HardnessIN_mmol_l | VirtualInHttp | "HardnessIN_mmol_l" : \v | mmol/l |
| HardnessOUT_CaCO3 | VirtualInHttp | "HardnessOUT_CaCO3" : \v | ppm CaCO³ |
| HardnessOUT_fH | VirtualInHttp | "HardnessOUT_fH" : \v | °fH |
| HardnessOUT_dH | VirtualInHttp | "HardnessOUT_dH" : \v | °dH |
| HardnessOUT_mmol_l | VirtualInHttp | "HardnessOUT_mmol_l" : \v | mmol/l |
| HolidayModeStartTime | VirtualInHttp | "HolidayModeStartTime" : \v | <v> |
| RegenerationCountSinceSetup | VirtualInHttp | "RegenerationCountSinceSetup" : \v | <v> |
| RegenerationCounterColumn1 | VirtualInHttp | "RegenerationCounterColumn1" : \v | <v> |
| RegenerativSinceSetup_g | VirtualInHttp | "RegenerativSinceSetup_g" : \v | g |
| RegenerationCounterColumn2 | VirtualInHttp | "RegenerationCounterColumn2" : \v | <v> |
| ShowError | VirtualInHttp | "ShowError" : \v | <v> |
| WaterTreatedCurrentDay_l | VirtualInHttp | "WaterTreatedCurrentDay_l" : \v | l |
| WaterTreatedCurrentMonth_l | VirtualInHttp | "WaterTreatedCurrentMonth_l" : \v | l |
| WaterTreatedCurrentYear_l | VirtualInHttp | "WaterTreatedCurrentYear_l" : \v | l |
FAQ
No questions have been answered yet.
Questions and answers
Important information for set up missing
OpenAfter BWT Perla is on latest beta Firmware the customer needs to activte the API in settings->General->Connection. This information is missing. Maybe you also want to mention that the Firma 2.02XX is still in beta stage and needs to be used at own risk
No replies
Aqua Stop
OpenIs there also a API call for AQA Stop function available? Would be nice to stop the water if something happens.
1 reply
Already found the description of the api so probably there is no possibility available to call it: https://www.bwt.com/de/-/media/sharepointpdfs/productdocuments_plm_dt/0000022379.pdf?rev=b748a66b3cc5458da5db8c2b6299689e
Log in to rate, comment or ask a question. Log in
Ratings and comments
No ratings or comments yet.
Log in to rate, comment or ask a question. Log in