Brink Flair

by STORC TZB s.r.o.No rating yet337 downloads

Content languageEnglish

Description

ENG: CO2 sensors ensure optimal ventilation of the home by automatically adjusting the airflow based on the CO2 content. The airflow is determined by the CO2 sensor, which requires the highest level. The CO2 sensor(s) only regulate the unit when the position switch/air control is set to position 1; when the position switch is in position 0 or on the fan symbol (absent) the CO2 control does not operate. Depending on the minimum and maximum (set) PPM values, the CO2 control adjusts the airflow between setting 1 (low setting) and setting 3 (high setting).

1 = Air flow value 2 = Amount of CO2 in the area where the CO2 sensors are located Q Min = Minimum airflow setting 1; for example Flair 325 (Plus) factory setting step 1.2 = 100 m3 /h Q Max = Maximum airflow setting 3; for example Flair 325 (Plus) factory setting step No. 1.4 = 250 m3 /h Min. PPM = Minimum (set) PPM value; for example Flair 325 (Plus) factory setting step no. 6.2 = 400 PPM Max. PPM = Maximum (set) PPM value; for example Flair 325 (Plus) factory setting step No. 6.3 = 1200 PPM

Modbus address: AI reading values : Q Min= 6001 Q Max = 6003 Min. PPM = 6151 Max. PPM = 6152 AQ write values : Q Min= 6001 Q Max = 6003 Min. PPM = 6151 Max. PPM = 6152 For proper functionality, flow control using Co2 LOXONE must be 8000=2, and flow control using 8002. For more details, refer to the modbus UWA2-B/UWA2-E manual.

CZ: CO2 čidla zajišťují optimální ventilaci obydlí díky automatickému nastavení proudění vzduchu na základě CO2 obsahu. Proudění vzduchu určuje CO2 čidlo, které vyžaduje nejvyšší úroveň. CO2 čidlo (čidla) reguluje zařízení, pouze pokud je polohový přepínač/ovládání vzduchu nastaveno v poloze 1; když je polohový přepínač v poloze 0 nebo na symbolu ventilátoru (nepřítomnost) CO2 ovládání nefunguje. V závislosti na minimální a maximální (nastavené) hodnotě PPM regulace CO2 upravuje proudění vzduchu mezi nastavením 1 (nastavení nízké) a nastavením 3 (nastavení vysoké).

1 = Hodnota proudění vzduchu 2 = Množství CO2 v oblasti, kde jsou umístěna CO2 čidla Q Min = Nastavení minimálního proudění vzduchu 1; například Flair 325 (Plus) tovární nastavení krok č. 1.2 = 100 m3 /h Q Max = Nastavení maximálního proudění vzduchu 3; například Flair 325 (Plus) tovární nastavení krok č. 1.4 = 250 m3 /h Min. PPM = Minimální (nastavená) hodnota PPM; například Flair 325 (Plus) tovární nastavení krok č. 6.2 = 400 PPM Max. PPM = Maximální (nastavená) hodnota PPM; například Flair 325 (Plus) tovární nastavení krok č. 6.3 = 1200 PPM

Modbus address: AI čtení hodnot : Q Min= 6001 Q Max = 6003 Min. PPM = 6151 Max. PPM = 6152 AQ zápis hodnot: Q Min= 6001 Q Max = 6003 Min. PPM = 6151 Max. PPM = 6152 Pro správnou funkčnost řízení průtoků pomocí Co2 LOXONE musí být 8000=2, a řízení průtoku pomocí 8002. Více podrobností v návodu modbus UWA2-B/UWA2-E.

Inputs and outputs · 218

NameTypeUnit
Software version number 0Modbus<v.1>
Appliance TypeModbus<v.1>
Dipswitch valueModbus<v.1>
Serial number 0Modbus<v.1>
Serial number 1Modbus<v.1>
Serial number 2Modbus<v.1>
HRA (Heat Recovery Appliance) Active FunctionModbus<v.1>
Fan control typeModbus<v.1>
Ventilation modeModbus<v.1>
Hardware versionModbus<v.1>
Software version number 2Modbus<v.1>
Temperature sensor exhaust fanModbus°C
Software version number 1Modbus<v.1>
Current supply pressureModbusPa
Current exhaust pressureModbusPa
Fan Inlet StatusModbus<v.1>
Setpoint supply airModbusm3/h
Current value of supplyairModbusm3/h
Speed supply fanModbusRPM
Temperature sensorsupply fanModbus°C
Fan inlet sensor rel.humidityModbus%
Fan exhaust StatusModbus<v.1>
Setpoint flow exhaust airModbusm3/h
current value flowexhaust airModbusm3/h
MassFlow exhaust,actual valueModbusKg/h
Speed exhaust fanModbusRPM
Temperature sensor exhaust fanModbus°C
Fan exhaust sensor rel.humidityModbus%
Bypass statusModbus<v.1>
Status preheaterModbus<v.1>
Capacity of preheaterModbus%
Frost statusModbus<v.1>
Frost heaterpowerModbus%
Flow switch positionModbus<v.1>
NTC1 temperatureModbus°C
NTC2 temperatureModbus°C
RHT Sensor HumidityModbus%
Signal output StatusModbus<v.1>
Status filterModbus<v.1>
eBus power statusModbus<v.1>
Current timeModbus<v.1>
Current dateModbus<v.1>
Operating timeModbus<v.1>
Filters used in daysModbus<v.1>
Filters used in m3/hModbus<v.1>
Total flow in m3/hModbus<v.1>
Geo heat exchangerStatusModbus<v.1>
CO2 sensor 1 statusModbus<v.1>
Value CO2 sensor 1Modbus<v.1>
CO2 sensor 2 statusModbus<v.1>
Value CO2 sensor 2Modbus<v.1>
CO2 sensor 3 statusModbus<v.1>
Value CO2 sensor 3Modbus<v.1>
CO2 sensor 4 statusModbus<v.1>
Value CO2 sensor 4Modbus<v.1>
Software version numberUIF Module(e.g. "S1.01.03.0001")Modbus<v.1>
Software version numberUIF Module(e.g. "S1.01.03.0001")Modbus<v.1>
Software version numberUIF Module(e.g. "S1.01.03.0001")Modbus<v.1>
Hardware versionnumber UIF Module (e.g."H1.1")Modbus<v.1>
Device TypeModbus<v.1>
Dipswitch valueModbus<v.1>
Language Data versionUIF Module (e.g."S1.01.03.0001")Modbus<v.1>
Language Data versionUIF Module (e.g."S1.01.03.0001")Modbus<v.1>
Language Data versionUIF Module (e.g."S1.01.03.0001")Modbus<v.1>
Software version nr UIFModule (e.g."S1.01.03.0001")Modbus<v.1>
Software version nr UIFModule (e.g."S1.01.03.0001")Modbus<v.1>
Software version nr UIFModule (e.g."S1.01.03.0001")Modbus<v.1>
Local UIF SwitchModbus<v.1>
Local Button valueModbus<v.1>
Software version nExtension ModuleUWA2-E (e.g."S1.01.03.0001")Modbus<v.1>
Software version nExtension ModuleUWA2-E (e.g."S1.01.03.0001")Modbus<v.1>
Software version nExtension ModuleUWA2-E (e.g."S1.01.03.0001")Modbus<v.1>
Hardware version nrExtension ModuleUWA2-E (e.g. "H1.1")Modbus<v.1>
Device TypeModbus<v.1>
Temperature NTC ExtensionModbus°C
Extension contact 1Modbus<v.1>
Extension contact 2Modbus<v.1>
Extension AnalogueInput 1ModbusV
Extension AnalogueInput 2ModbusV
Extension Relay output 1Modbus<v.1>
Dipswitch valueModbus<v.1>
Extension Relay output 2Modbus<v.1>
Extension Analogue Output 1ModbusV
Extension Analogue Output 2ModbusV
Flow preset 0Modbus<v.1>
Flow preset 1Modbus<v.1>
Flow preset 2Modbus<v.1>
Flow preset 3Modbus<v.1>
Switch default positionModbus<v.1>
Use display as switchModbus<v.1>
Imbalans allowedModbus<v.1>
Imbalance valueModbus<v.1>
Offset imbalance supplyModbus%
Offset imbalance exhaustModbus%
Bypass modeModbus<v.1>
Bypass temperature fromdwellingModbus°C
Bypass temperature from outsideModbus°C
Bypass temperature hysteresisModbus°C
Bypass boostModbus<v.1>
Bypass boost switch positionModbus<v.1>
Frost control minimum inlet temperatureModbus°C
Days before filter warningModbus<v.1>
External heater modeModbus<v.1>
Postheater setpointModbus°C
RHT (humidity) sensor modeModbus<v.1>
RHT (humidity) sensor sensitivityModbus<v.1>
CO2 sensor modeModbus<v.1>
CO2 sensor 1 low levelModbus<v.1>
CO2 sensor 1 high levelModbus<v.1>
CO2 sensor 2 low levelModbus<v.1>
CO2 sensor 4 high levelModbus<v.1>
CO2 sensor 2 high levelModbus<v.1>
CO2 sensor 3 low levelModbus<v.1>
CO2 sensor 3 high levelModbus<v.1>
CO2 sensor 4 low levelModbus<v.1>
Signal output SettingModbus<v.1>
Switch type Input 1Modbus<v.1>
Digital Input 1 functionModbus<v.1>
Digital input 1 supply fan functionModbus<v.1>
Digital Input 1 exhaust fan functionModbus<v.1>
Switch type Input 2Modbus<v.1>
Digital input 2 functionModbus<v.1>
Digital input 2 supply fan functionModbus<v.1>
Digital input 2 exhaust fan functionModbus<v.1>
Analogue input 2 ModeModbus<v.1>
Analogue Input 1 ModeModbus<v.1>
Analogue input 1 VminModbusV
Analogue input 1 VmaxModbusV
Analogue input 2 VminModbusV
Analogue input 2 VmaxModbusV
Geo-heat exchangerModbus<v.1>
Minimum temperature geo-heat exchangerModbus°C
Maximum temperaturegeo-heat exchangerModbus°C
Default geo heatexchanger Valve PositionModbus<v.1>
Geo heat exchangervalve outputModbus<v.1>
LanguageModbus<v.1>
Date formatModbus<v.1>
Time notationModbus<v.1>
Date Month DayModbus<v.1>
Date YearModbus<v.1>
TimeModbus<v.1>
DateTime RestModbus<v.1>
Modbus interface typeModbus<v.1>
Modbus slave addressModbus<v.1>
Modbus speedModbus<v.1>
Modbus control switched onModbus<v.1>
Request change in switch positionModbus<v.1>
Desired flow rate settingModbus<v.1>
Request StandbyModbus<v.1>
Reset filter warningModbus<v.1>
Appliance resetModbus<v.1>
Flow preset 0Modbus<v.1>
Flow preset 1Modbus<v.1>
Flow preset 2Modbus<v.1>
Flow preset 3Modbus<v.1>
Switch default positionModbus<v.1>
Use display as switchModbus<v.1>
Imbalans allowedModbus<v.1>
Imbalance valueModbus<v.1>
Offset imbalance supplyModbus%
Offset imbalance exhaustModbus%
Bypass temperature from dwellingModbus°C
Bypass temperature fromoutsideModbus°C
Bypass temperaturehysteresisModbus°C
Bypass boostModbus<v.1>
Bypass boost switchpositionModbus<v.1>
Frost control minimum inlet temperatureModbus°C
Days before filterwarningModbus<v.1>
External heater modeModbus<v.1>
Postheater setpointModbus°C
RHT (humidity) sensormodeModbus<v.1>
RHT (humidity) sensor sensitivityModbus<v.1>
CO2 sensor modeModbus<v.1>
CO2 sensor 1 low levelModbus<v.1>
CO2 sensor 1 high levelModbus<v.1>
CO2 sensor 2 low levelModbus<v.1>
CO2 sensor 2 high levelModbus<v.1>
CO2 sensor 3 low levelModbus<v.1>
CO2 sensor 3 high levelModbus<v.1>
CO2 sensor 4 low levelModbus<v.1>
CO2 sensor 4 high levelModbus<v.1>
Signal outputModbus<v.1>
Switch type Input 1Modbus<v.1>
Digital Input 1 functionModbus<v.1>
Digital input 1 supply fan functionModbus<v.1>
Bypass modeModbus<v.1>
Digital Input 1 exhaustModbus<v.1>
Switch type Input 2Modbus<v.1>
Digital input 2 functionModbus<v.1>
Digital input 2 supply fan functionModbus<v.1>
Digital input 2 exhaust fan functionModbus<v.1>
Analogue Input 1 ModeModbus<v.1>
Analogue input 1 VminModbusV
Analogue input 1 VmaxModbusV
Analogue input 2 ModeModbus<v.1>
Analogue input 2 VminModbusV
Analogue input 2 VmaxModbusV
Geo-heat exchangerModbus<v.1>
Minimum temperature geo-heat exchangerModbus°C
Maximum temperature geo-heat exchangerModbus°C
Default geo heat exchanger Valve PositionModbus<v.1>
Geo heat exchanger valve outputModbus<v.1>
LanguageModbus<v.1>
Date formatModbus<v.1>
Time notationModbus<v.1>
Date Month DayModbus<v.1>
Date YearModbus<v.1>
TimeModbus<v.1>
DateTime RestModbus<v.1>
Modbus interface typeModbus<v.1>
Modbus slave addressModbus<v.1>
Modbus speedModbus<v.1>
Modbus control switched onModbus<v.1>
Request changein switch positionModbus<v.1>
Desired flow rate settingModbus<v.1>
Request StandbyModbus<v.1>
Reset filter warningModbus<v.1>
Appliance resetModbus<v.1>