Belimo Room Operating Unit Modbus RTU

by BELIMO AutomationNo rating yet338 downloads

Content languageEnglish

Description

For measuring the temperature, humidity and CO₂ in the room and adjusting temperature and ventilation setpoints.

Inputs and outputs · 51

NameTypeUnit
Room Temperature in CelciusModbus°C
Room Temperature in Selected UnitModbus°C
Relative HumidityModbus%
CO2 Value of the RoomModbusppm
Dew Point Temperature in CelciusModbus°C
Dew Point Temperature in Selected UnitModbus°C
Air Quality StatusModbus<v>
Digital InputModbus<v>
Bus TerminationModbus<v>
Serial Number Device – 1st partModbus<v>
Serial Number Device – 2nd partModbus<v>
Serial Number Device – 4th partModbus<v>
Firmware VersionModbus<v.1>
Display Warning IconModbus<v>
Display Window IconModbus<v>
Room/Zone Temperature Setpoint in CelciusModbus°C
Set Ventilation StageModbus%
System Operation ModeModbus<v>
Ventilation Stage Control ModeModbus<v>
Heating and Cooling Application StatusModbus<v>
Enable Local AdjustmentModbus<v>
Room/Zone Temperature Setpoint in Selected UnitModbus°C
Relative Room/Zone Temperature Setpoint in CelciusModbus°C
Relative Room/Zone Temperature Setpoint in Selected UnitModbus°C
Room Temperature OffsetModbusK
Relative Humidity OffsetModbus%
CO2 Value OffsetModbusppm
CO2 Limit for Good Air QualityModbusppm
CO2 Limit for Medium Air QualityModbusppm
Air Quality IndicationModbus<v>
Window Icon FunctionModbus<v>
Mode Temperature on DisplayModbus<v>
Display Ventilation StagesModbus<v>
Select the preferable temperature unitModbus<v>
Unit for temperature shown on displayModbus<v>
Select the preferable differential temperature unitModbus<v>
Light/Dark Color SchemeModbus<v>
Display Room/Zone TemperatureModbus<v>
Display Relative HumidityModbus<v>
Display CO2 ValueModbus<v>
Display Heating/Cooling IconModbus<v>
Warning Icon FunctionModbus<v>
Eco Button ModeModbus<v>
Display Boost ButtonModbus<v>
Mode On/Off ButtonModbus<v>
Boost Mode DurationModbuss
Temperature Setpoint TypeModbus<v>
Default Room Temperature SetpointModbus<v.1>
Adjustment range temperature setpointModbus<v>
Ventilation Stage ConfigurationModbus<v>
Ventilation Control ModeModbus<v>

FAQ

No questions have been answered yet.

Ratings and comments

No ratings or comments yet.

Questions and answers

  1. Lesen funktioniert / schreiben leider nicht

    Open

    Guten Morgen,

    wir haben den Belimo RO Unit Modbus in unser System eingebunden. Nach der Elektrifizierung sind die Symbole auf dem Display nicht mehr zu sehen, was wahrscheinlich so richtig ist. Wir können die Sensorwerte auslesen, jedoch wenn wir zb. eine 1 zu dem Register 10 ( display warning icon ) senden passiert nichts. Was könnte die Ursache sein ? Gibt es eine ausführliche Anleitung ? Danke und Grüße Jörg Epping

    No replies

Report this entry

Report abuse

You have to be logged in to report an entry. Log in