Skip to content
Image of AMS Reader Pow-U_Pow-K
Template

AMS Reader Pow-U_Pow-K

by eReitan ConsultingNo rating yet750 downloads

Content languageEnglish

Description

AMS reader Pow-U and Pow-K to be connected to activated HAN-port in your AMS meter like Aidon, Kaifa, Kamstrup, Sanxing, Sagemcom etc. to read out real time data like: power, voltage, ampere, etc.

Supports IEC-62056-7-5 or IEC-62056-21 compliant meters.

Pow-U and Pow-K can also be configured with a EntsoE API token to read out energy prices / Day a-head prices.

For Aidon and Kaifa Pow-U to be used:

For kamstrup Pow-K to be used:

Not recommended to be used in combination with external HAN adapter like Embriq or Rejlers. That is used for Landis Gyr and some Aidon meters.

For more info https://amsleser.no

Inputs and outputs · 42

NameTypeCommandUnit
Maximum power consuptionVirtualInHttp"im":\v
Main fuse sizeVirtualInHttp"mf":\v
Maximum power productionVirtualInHttp"om":\v
Active importVirtualInHttp"i":\v
Active exportVirtualInHttp"e":\v
Reactive importVirtualInHttp"ri":\v
Accumulated importVirtualInHttp"ic":\v
Accumulated exportVirtualInHttp"ec":\v
Accumulated reactive importVirtualInHttp"ric":\v
Accumulated reactive exportVirtualInHttp"rec":\v
L1 voltageVirtualInHttp"u1":\v
L2 voltateVirtualInHttp"u2":\v
L3 voltageVirtualInHttp"u3":\v
L1 currentVirtualInHttp"i1":\v
L2 currentVirtualInHttp"i2":\v
Power factorVirtualInHttp"f":\v
L2 power factorVirtualInHttp"f2":\v
L3 currentVirtualInHttp"i3":\v
L1 power factorVirtualInHttp"f1":\v
L3 power factorVirtualInHttp"f3":\v
ESP voltageVirtualInHttp"v":\v
WiFi RSSIVirtualInHttp"r":\v
TemperatureVirtualInHttp"t":\v
Uptime in secondsVirtualInHttp"u":\v
Free memory in bytesVirtualInHttp"m":\v
ESP statusVirtualInHttp"em":\v
HAN statusVirtualInHttp"hm":\v
WiFi statusVirtualInHttp"wm":\v
MQTT statusVirtualInHttp"mm":\v
Last MQTT errorVirtualInHttp"me":\v
Current hour priceVirtualInHttp"p":\v
Internal clockVirtualInHttp"c":\v
Meter typeVirtualInHttp"mt":\v
Current active month thresholdVirtualInHttp],"t":\v
Max average of configured amount of hoursVirtualInHttp"x":\v
Current active month thresholdVirtualInHttp"t":\v
Real time calculation this hourVirtualInHttp"h":{"u":\v
Real time calculation this hourVirtualInHttp"c":\v
Real time calculation this monthVirtualInHttp"m":{"u":\v
Real time calculation todayVirtualInHttp"d":{"u":\v
Real time calculation todayVirtualInHttp"d":{"u":\s10\v
Real time calculation this monthVirtualInHttp"m":{"u":\s11\v

FAQ

No questions have been answered yet.

Ratings and comments

No ratings or comments yet.

Questions and answers

No questions have been asked yet.

Report this entry

Report abuse

You have to be logged in to report an entry. Log in