factory communication settings:

Protocol: Modbus RTU (HEX) Baudrate: 9600 Parität: none Stopbits: 1 Data Bit: 8

communication framework:

Protocol: Modbus RTU (HEX) -8 Bit Slave Adress(0x01) -FunctionCode (e.g. 0x03/0x10) -N x 8 Bit Data -> Register Adress(16 Bit); NumberofCoils (16 Bit, e.g. 0x09 forall Registers ifstartingwithAdress0x00); ActualData (e.g. 16 Bit integer) -16 Bit CyclicRedundancyCheck (CRC) formessageverification

Inputs and outputs · 15

NameTypeUnit
0=EVSE status 1 Ready, 2 Connected, 3 ChargingModbus<v.1>
1=Actual Modbus ID, default 1Modbus<v.1>
2=Installed Amps (Read from rotary switch)Modbus<v.1>
3=Force unlock (Always 0)Modbus<v.1>
4=Disable Charging-StationModbus<v.1>
5=Trottled AModbus<v.1>
6=New Modbus IDModbus<v.1>
7=Write new ID to EPROMModbus<v.1>
8=Reboot UnitModbus<v.1>
3=Force unlockModbus<v.1>
4=Disable Charging-StationModbus<v.1>
5=Set actual Amps, must be higher than 6AModbus<v.1>
6=Write new Modbus IDModbus<v.1>
7=Write parameter 6 to EPROMModbus<v.1>
8=Unit rebootsModbus<v.1>