ModBus template for reading values from Sofar Solar Hybrid inverter over RTU.

Scope:

- PV production - Grid consumption - Overall consumption - SOC load/unload level - SOC storage level - inverter status

If your ModBus communication with Sofar goes silent over time consider contacting support for a fixed firmware with buffer overflow error fixed.

Inputs and outputs · 15

NameTypeUnit
StatusModbus<v.1>
Power_Bat1ModbuskW
SOC_Bat1Modbus<v>
PV_Generation_TotalModbuskWh
Energy_Purchase_TotalModbuskWh
Energy_Selling_TotalModbuskWh
ActivePower_Output_TotalModbuskW
ActivePower_PV_ExtModbus<v.1>
Power_PV_TotalModbus<v.2>
Power_PV1Modbus<v.2>
Power_PV2Modbus<v.2>
ActivePower_Load_TotalModbus<v.2>
ActivePower_Output_L1NModbus<v.2>
ActivePower_Output_L2NModbus<v.2>
ActivePower_PCC_TotalModbuskW

FAQ

No questions have been answered yet.

Ratings and comments

No ratings or comments yet.

Questions and answers

  1. Modbus RTU connection

    Open

    Hello,

    may I ask how you have the connector in the COM port of the inverter? What pins are you using?

    And how do you have the communication not set up in Config? What port are you using?

    Is something more than a standard modbus extension needed? ?

    Thank you!

    1 reply

    1. Loxone Config: * baud rate 9600 * stop bit: 1 * parity: none Standard Loxone ModBus extension was used. Nothing else.

      I used pins as in inverter's manual. Pins 1 and 3.

  2. Write commands

    Open

    Hello, you should also be able to change values ​​in the inverter. I can't do that. Does anyone have a solution?

    Greetings Christian

    No replies