Description

With this example config you can realize the Loxone side integration of a meter into the Smart-Me Cloud.

In the Smart-Me Wiki you will find a detailed description of how to prepare everything on the Smart-Me side and obtain the necessary data. https://dok.smart-me.com/drittsysteme/loxone

Insert the downloaded template into your config.

This creates a virtual output, for which you still have to enter your Base64 coding in the header, which you receive from the creation of the meter at smart-me.

In the example config, there is a text generator in which the body for updating the meter value is included. You must enter the following in this: Id, Name and Serialnumber, you receive these values when you create the meter on the smart-me site.

Here are the raw data for an electric meter.

{ “Id": ‘’, “Name": ‘’, “Serial": , “DeviceEnergyType": 1, “ActivePower": <v1.2>, “CounterReading": <v2.2>, “CounterReadingExport": <v3.2>, }

For more values and other counters, you can find more settings in the Smart-Me documentation: https://api.smart-me.com/swagger/index.html

Inputs and outputs · 1

NameTypeCommandUnit
Zähler 1VirtualOut/Devices

FAQ