Template

Novelan Heating & Cooling

by AIT Deutschland GmbHNo rating yet661 downloads

Content languageEnglish

Description

This template allows you to control your Novelan Heatpump without Gateway over Modbus TCP.

The Modbus RTU interface is only available for Novelan internal service purposes.

The Novelan WPR-C is the control system for Air/Water, Brine/Water, Water/Water Heatpumps from Novelan.

_________________________________________________________________________________________________

The choice of paring Novelan systems with Loxone offers the possibility of:

  • Integrating demand-based heating and cooling depending on e.g. presence or the protection of open windows
  • Active integration in interaction with e.g. PV- systems in a Loxone Energy Management
  • Using flexible electricity tariffs with the Spot Price Optimizer.
  • Use statistics ore individual notifications
  • Create your own individual schematics
  • Reduce cycles and operating hours of your Novelan Heatpump
  • Create e.g. yearly operation goals like certain annual runtime forces for hybrid systems e.g. (Heatpump 60% amount of energy, Gas heater 40% amount of energy) to fulfill the requirements of your local government.
  • Grid management according to §14a ENWG in Germany
  • In addition to the electrical power, the current and total thermal energy can also be visualized via the Loxone Energy Flow Monitor. To the compact overview for e.g. contractors.
  • Influence on the hot water circulation pump by controlling via the presence detectors.
  • Increased security through leakage detection or activation of IP cameras in the plant room. 

_________________________________________________________________________________________________

To enable communication between the Novelan and Loxone, you must activate the Modbus server within the Novelan heatpump:

The detailed description can be found in the Modbus instructions in the appendix. 

1. Obtain the USB stick (one-off costs) from your Novelan partner. 

It contains a license and the software. 

2. Download the "Novelan-GLT" software to be able to make settings 

3. Activate the Modbus server using the Novelan GLT software

Please note that some of the devices listed as compatible can only heat and do not offer a cooling function as described in the UseCase.

_________________________________________________________________________________________________

With our step by step manual for collecting the heating or cooling demand and forwarding it to the Novelan Lux, we enable the interaction of the individual room control with the central heating/cooling system of Novelan.

Please take a look on the Loxone Config sample file in the Library download area.

__________________________________________________________________________________________________

Structure: [Example in Cascade with more heatpumps]


_________________________________________________________________________________________________

Novelan helpcenter and download area:

[Novelan is only sold in the DACH region, so there is only German documentation available]


  • If you need actual documentation of your Novelan heatpump please use the following link:

  • If you need the modbus documentation please use the following link:

__________________________________________________________________________________________________

UseCase: Integration of a WPR-C:

Residential building with heating, warm water storage and heating circuits.

  • Device Air/Water Heatpump Novelan LWAV with WPR-C operation unit
  • Warm water storage tank --> Controlled by Loxone
  • Heating/Cooling buffer
  • Mixing circuit heating HC1 (e.g. radiators) --> Main PCB WPR-C 2.1 --> Controlled by Loxone
  • Mixing circuit heating & cooling HC2 (e.g. ceiling heating) --> Extension PCB 2.1 --> Controlled by Loxone


[detailed schematic with cable layout can be found in the template of the download area]

Inputs and outputs · 20

NameTypeUnit
Actual Heatpump Flow temperature [TVL]Modbus
Actual Heatpump Return temperature [TRL]Modbus
Acutal Buffer temperature sensor bottom [TRLext]Modbus
Actual Warm Water tank temperature [TBW]Modbus
Actual Buffer temperature sensor top [TB2]Modbus
Actual Heatpump Source temperature [TWE]Modbus
State Heatpump Operating HoursModbus
State Heatpump SystemModbus
Actual Outdoor temperature [TA]Modbus
State Warm Water tank Target temperatureModbus
State Buffer temperature Target temperatureModbus
State Heating Operation modeModbus
State Cooling Operation modeModbus
Actual Flow temperature HC2 [TB1]Modbus
Buffer Target temperature setpointModbus
Warm water Target temperature setpointModbus
Warm water operation modeModbus
Heatpump Heating operation modeModbus
Flow Target temperature HC2Modbus
Heatpump Cooling operation modeModbus